n
Set Ethernet parameters
The dialog field for pre-setting an Ethernet address is to be found
at
‘Start
è
Settings
è
Network and Dial-up Connections’
. The
default setting is address assignment via DHCP.
Please consider with the manual assignment of IP
addresses that these are not identical for both interfaces. If
you accidentally have assigned to the same IP address to
both interfaces, then only one interface icon is shown at
‘Network and Dial- up Connections’ . By switching to
DHCP, you receive 2 Interface icons again and can con-
figure them individually.
n
System properties (System)
Here you receive information about the version of the current Win-
dows
Ò
operating system, the memory load and sharing (altera-
tions here are not taken over into the registry) and about the copy-
right. The register Device Name allows you to change the
device
name
that is e.g. shown during Ethernet communication.
n
Set the back-lighting
Via
‘Start
è
Settings
è
Control Panel
è
Power Properties’
you
may set the break time and the dimming of the back-lighting. For
this choose AC Power at "Power Scheme" and then set the appro-
priate time.
A set suspend mode shuts down the Touch Panel com-
pletely. By switching the power supply off and on again
you can restart the Touch Panel.
To configure the optional MPI/DP interface on the Touch Panel start
via
‘Start
è
Settings
è
Control Panel’
or via "Settings" in the VIPA
Startup-Manager the tool "MPI/DP Slave Configuration".
Default: MPI - Address 1
The following settings are only required if not communicate via
Movicon.
Via mode the interface could be set up on "DP slave".
Configuration MPI/DP
slave
VIPA HMI
Deployment under Windows CE 6.0 Core
Operating system Windows
Ò
Embedded CE 6.0 Core> Structure
HB160 | TP-ECO | 62P-NHC0 | GB | 16-02