background image

9 pin SubD jack

An RJ45 jack provides the interface to the twisted pair cable, required for Ethernet.

Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be

connected.

For project transfer with Microsoft ActiveSync a programming cable can be connected

using the "Slave"-USB-B interface.

The USB-A interface of your PC can be connected to the "Slave"-USB-B interface of your

Touch Panel deploying the USB programming cable.

The USB programming cable is delivered by YASKAWA with order No. 670-0KB10.

The Touch Panel has got an integrated power supply. The power supply has to be pro-

vided with DC 24V (20.4 ... 28.8V). For this you find an according DC 24V slot on the

bottom side.

The power supply is protected against inverse polarity and overcurrent. The battery for

the clock of the Touch Panel is an accumulator with a suitable charging circuit. This accu-

mulator is maintenance-free and does not need to be exchanged within the life span of

the Touch Panel.

2.3.3  Memory management

The following memory systems are available for every Touch Panel:

n

256Mbyte work memory

n

512Mbyte user memory (ca. 380Mbyte for user data)

n

USB storage media connected via "Host"-USB-A interface

n

Slot for CF (Type II)

n

Slot for MMC/SD

Please only use memory cards formatted with FAT(32)!

Every Touch Panel has a work memory with a size of 256Mbyte. The work memory is not

buffered and is deleted after shut down. Please consider that also registry entries are

stored in the work memory that are set back to default settings after the next re-boot. You

can save them permanently by means of the 

KuK Tools

 (within consignment).

MPI/PROFIBUS DP inter-

face

Ethernet connection

"Host"-USB-A

"Slave"-USB-B

Power supply

Overview

Work memory

VIPA HMI

Hardware description

Structure > Memory management

HB160 | TP | 62M-JID0 | en | 20-20

 

12

Содержание VIPA TP 612C

Страница 1: ...TP 62M JID0 Manual HB160 TP 62M JID0 en 20 20 VIPA HMI Touch Panel TP 612C...

Страница 2: ...62M JID0_000_TP612C 3 EN 2020 YASKAWA Europe GmbH Ohmstra e 4 91074 Herzogenaurach Tel 49 9132 744 0 Fax 49 9132 744 186 Email info yaskawa eu com Internet www yaskawa eu com...

Страница 3: ...r 24 3 3 Connection to a PLC system 28 3 4 Operating system Windows Embedded CE 6 0 Prof 28 3 4 1 General 28 3 4 2 Structure 30 3 5 Communication via ActiveSync 34 3 6 Integrated Server 36 3 6 1 Gener...

Страница 4: ...Descriptions may be included for units which are not present at the customer site The exact scope of delivery is described in the respective purchase contract Hereby YASKAWA Europe GmbH declares that...

Страница 5: ...IPA Touch Panel 62M JID0 It contains a description of the structure project engineering and deployment Product Order number as of state HW BS TP 612C 62M JID0 01 Windows CE 6 0 Prof The manual is targ...

Страница 6: ...able to all personnel in the n project design department n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the component...

Страница 7: ...ules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices...

Страница 8: ...n Windows CE 6 0 Prof n 62M JID0 CB Movicon 11 CE Standard 4096 I O bytes n Processor Xscale 1 1GHz n Work memory 256Mbyte n User memory 512Mbyte n 380Mbyte memory for user data n CF Card II and MMC S...

Страница 9: ...USB A USB B 2xEthernet RJ45 Switch 2 3 Structure 2 3 1 Overview 1 Slot for storage medium CF SD MMC 2 Connection for interfaces and power supply 3 Display with touch sensitive area touch screen 1 Comp...

Страница 10: ...ack for Ethernet communication 7 RJ45 jack for Ethernet communication 8 Slot for DC 24V voltage supply 9 Slot for CF SD MMC storage medium Please make sure that the Touch Panel always has to be suppli...

Страница 11: ...115 2kBaud n Serial bus connection in 2 wire technology using half duplex mode 9 pin SubD plug n Interface is compatible to the COM interface of a PC n Logical signals as voltage levels n Point to poi...

Страница 12: ...anel is an accumulator with a suitable charging circuit This accu mulator is maintenance free and does not need to be exchanged within the life span of the Touch Panel 2 3 3 Memory management The foll...

Страница 13: ...slot until the impact To remove the card touch it at the pulling edge and pull On this slot you can plug storage modules of the type SD or MMC The card may be plugged and removed during runtime and i...

Страница 14: ...allation depth 45mm The degrees of protection are only guaranteed when the following is observed Material thickness at the mounting cut out 1 5 6mm The deviation from the plane for the panel cut out i...

Страница 15: ...tion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14...

Страница 16: ...lses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data 2 6 1 62M JID0 CB Order no 6...

Страница 17: ...tor Sub D 9 pin female Serial COM1 RS232 COM1 connector Sub D 9 pin male Serial COM2 RS422 485 isolated COM2 connector Sub D 9 pin female Number of USB A interfaces 2 USB A connector USB A host Number...

Страница 18: ...325 mm x 263 mm x 7 5 mm Rear panel 309 mm x 247 mm x 45 mm Installation cut out Width 311 mm Height 249 mm Minimum 1 5 mm Maximum front panel thickness 6 mm Net weight 3674 g Environmental conditions...

Страница 19: ...Rechargeable Lithium Battery Load time for 50 buffering period 10 h Load time for 100 buffering period 48 h Accuracy max deviation per day 10 s Operating controls Touchscreen resistive Touch function...

Страница 20: ...t 0 25 A s Power loss 15 8 W Status information alarms diagnostics Supply voltage display yes Mechanical data Housing Protection type Material die cast aluminum Mounting via integrated pivoted lever P...

Страница 21: ...Order no 62M JID0 CX Certifications UL certification yes KC certification VIPA HMI Hardware description Technical data 62M JID0 CX HB160 TP 62M JID0 en 20 20 21...

Страница 22: ...cabinet fronts the Touch Panel requires the following front plate cutting Touch Panel W x H in mm 62M JID0 311 x 249 The fixing technique is integrated in the casing of the Touch Panel and accessible...

Страница 23: ...rs to the CageClamps like this 1 Round opening for wires 2 Locking orange for screwdriver 3 Test point for 2mm test tip The picture on the left side shows the cabling step by step from top view 1 For...

Страница 24: ...ouch Panel is provided by power supply the Startup Manager will be loaded At the first startup of the Startup Manager the following start screen appears n There is a button on the initial screen with...

Страница 25: ...irmware images is shown which are available on the panel and connected storage media These images will be listed with create data and version number Choose your new image If the selected image is not...

Страница 26: ...ollowing batch files Start VIPA Webbrowser bat Start VIPA Webserver and Browser fullscreen bat Start VIPA Webserver and Browser bat Start VIPA Webserver bat n Under Delay Time you can adjust a delay t...

Страница 27: ...egistry settings for the back light the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and the s...

Страница 28: ...the application courses in the PLC according to the configured processes Via dia logues configured before process values may be monitored graphically altered and eval uated 3 4 Operating system Windo...

Страница 29: ...g on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the dragging that selects the touched objects Characteristics with Windows Embedde...

Страница 30: ...your Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no button for minimizing The switc...

Страница 31: ...allows you to select one of the available software keyboards At the moment the following standard keyboards are implemented At pushed Shift key At pushed a key Please note that can exclusively be ent...

Страница 32: ...re keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides the keyboard aga...

Страница 33: ...nment via DHCP n System properties System Here you receive information about the version of the current Windows operating system the memory load and sharing alterations here are not accepted into the...

Страница 34: ...a mobile device and a PC via USB Many devel oper tools res SCADA project engineering tools use ActiveSync for the data transfer Before you can access the Touch Panel from the PC via ActiveSync you hav...

Страница 35: ...ouch Panel The USB device Touch Panel is recognized and the dialog window new part nership opens 2 Choose yes for fixing a partnership and push Next 3 In the opening window de activate all synchroniza...

Страница 36: ...ed in the description of the server A client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a re...

Страница 37: ...on your Touch Panel 3 As soon as your Touch Panel is connected via Ethernet you may monitor the IP address data via in the taskbar 4 After you ve confirmed the pre settings start your ftp client e g W...

Страница 38: ...elete and create files and directories You may also start applications Terminating an application is not possible The establishing of a Telnet connection is password protected and has the following ap...

Страница 39: ...he VNC server is on delivery deactivated Due to software reasons YASKAWA does not support the VNC server function With Autostart you can select the automatic startup of the VNC server via the Startup...

Страница 40: ...sources in a Microsoft network like drives and printer Here you may assign existing public directories or printer in the network to local directories or printer in the Touch Panel Condition for this i...

Страница 41: ...rname guest Input net use data testserver archiv user guest The connected network drive is then available via network data at the Touch Panel The configuration of a network printer happens with the fo...

Страница 42: ...the network connection to the drive archive of test server To save the settings also after power on you have to store them to the registry with START Programs KuK_Tools KuK Tools Store Terminate netwo...

Страница 43: ...erent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free...

Страница 44: ...lkie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following...

Страница 45: ...special EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrica...

Страница 46: ...ltage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts h...

Страница 47: ...e groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installe...

Страница 48: ...e of the equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is c...

Страница 49: ...the cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and t...

Страница 50: ...Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutra...

Страница 51: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunc...

Отзывы: