Range of values:
0030h = 1µs
0300h = 16µs
0060h = 2µs
0600h = 32µs
00C0h = 4µs
0900h = 48µs
0180h = 8µs
0C00h = 64µs
Other values are not allowed!
With the "listening mode" the transmission rate is irrelevant. Enter the
transmission rate here. This corresponds the clock frequency to com-
municate with the connected encoder. These data may be found in
the data sheet of your encoder.
Range of values:
0018h = 2MHz
0060h = 500kHz
0020h = 1.5MHz
00C0h = 250kHz
0030h = 1MHz
0180h = 125kHz
Other values are not allowed!
Depending on the encoder besides the encoder value further bits
were transferred. The number of bits, attached to the encoder value,
may be removed by right-shifting the encoder value by means of the
normalization. The normalization of the encoder value takes place via
the module always after a possible gray-binary transformation. More
about this may be found in the data sheet of your encoder.
Range of values:
00h ... 0Fh = 0bit ... 15bit
Enter here the bit length of the encoder data. Depending on the
encoder the encoder data consists of the current value with attached
bits. Please enter here the whole length of the data. These data may
be found in the data sheet of your encoder.
Range of values:
Hex
Bit
Hex
Bit
Hex
Bit
07
8
10
17
19
26
08
9
11
18
1A
27
09
10
12
19
1B
28
0A
11
13
20
1C
29
0B
12
14
21
1D
30
0C
13
15
22
1E
31
0D
14
16
23
1F
32
0E
15
17
24
BAUD Transmission
rate
NORM Normalization
LGTH Bit length
encoder data
VIPA System SLIO FM 050S
Deployment
Parameter data
HB300 | FM | 050-1BS00 | GB | 15-11