background image

The CPUID instruction of some newer CPUs will return a value

greater than 3. The default is disabled because this problem does not

exist in the Windows series operating systems. If you are using an

operating system other than Windows, this problem may occur. To

avoid this problem, enable this field to limit the return value to 3 or

less than 3.
Disabled - (default) All of the CPUID functions are supported.
Enabled - Limit the return value to 3 or less than 3.

This section is used to configure the IDE devices.

Enables or disables SATA controller.

Configures the SATA as IDE or AHCI mode.
IDE

- This option configures the serial ATA drives as parallel ATA

physical storage device.

AHCI - This option configures the serial ATA drives to use AHCI

(AdvancedHost Controller Interface). AHCI allows the storage

driver to enable the advanced serial ATA features which will

increase storage performance.

This section is used to configure USB devices, such as keyboard,

mouse and hub.

Limit CPUID Maximum

Submenu "IDE Configu-

ration"

SATA Controller(s)

Configure SATA as

Submenu "USB Config-

uration"

VIPA HMI

BIOS setup

Advanced

HB160 | PPC | 67S-PNL0 | GB | 16-22

 

40

Содержание VIPA 67S-PNL0

Страница 1: ...PPC 67S PNL0 Manual HB160 PPC 67S PNL0 GB 16 22 VIPA HMI Panel PC PPC021 ES...

Страница 2: ...67S PNL0_000_PPC021ES 4 GB 2016 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Страница 3: ...ard 25 3 3 Commissioning 26 3 3 1 VIPA Startup Manager 26 3 4 Connection to a PLC system 29 3 5 Operating system Windows Embedded Standard 7 30 3 5 1 General 30 3 5 2 Structure 31 4 BIOS setup 36 4 1...

Страница 4: ...com Every effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing Nevertheless the authors retain the right to modify the in...

Страница 5: ...91074 Herzogenaurach Germany Telefax 49 9132 744 1204 EMail documentation vipa de Contact your local VIPA Customer Service Organization representa tive if you encounter problems with the product or ha...

Страница 6: ...useful tips 1 3 Safety information The system is constructed and produced for n communication and process control n general control and automation tasks n industrial applications n operation within th...

Страница 7: ...e carried out when the system has been disconnected from power Installation and hardware modifications only by prop erly trained personnel The national rules and regulations of the respective country...

Страница 8: ...les that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the conse quent implementation of protection devices...

Страница 9: ...FT panel 16 7 M color n PCAP multitouch n Display resolution 1920 x 1080 n Intel Atom Processor D2550 Dualcore 1 86GHz 1M L2 Cache n Work memory 2x 204Pin DDR3 SO DIMM Socket 2GB DDR3 n User memory 16...

Страница 10: ...nterface COM 1 6 4x Host USB A interface 7 RJ45 jack for Ethernet communication LAN 2 8 RJ45 jack for Ethernet communication LAN 1 9 3 5mm Audio Line out 10 Power switch pushbutton 11 Slot for CFast s...

Страница 11: ...itch pushbutton The Panel PC starts automatically when the power supply is switched on But you can change the configuration in the BIOS setup so that the Panel PC has to be switched off by the power s...

Страница 12: ...p to 115 2kbit s RS422 interface n Logical conditions as voltage difference between 2 twisted lines n Serial bus connection full duplex four wire operation n Line length 250m at 115 2kbit s 1200m at 1...

Страница 13: ...VIPA HMI Hardware description Structure Interfaces HB160 PPC 67S PNL0 GB 16 22 13...

Страница 14: ...3 3 Memory management n 2GB work memory n 16GB SSD user memory n USB storage media using Host USB A interface n Slot for CFast memory card The Panel PC has a work memory with a size of 2GB The work m...

Страница 15: ...PC2 GND PC14 VCC3 PC3 n c PC15 GND PC4 n c PC16 GND PC5 n c PC17 CFAST_CDO Prior to removing the CFast card make sure the unit s power is off and disconnected from the power supply 2 4 Dimensions For...

Страница 16: ...4 20mm The degrees of protection are only guaranteed when the following is observed The material thickness of the installation cut out is 3 12mm The deviation from the plane for the panel cut out is 0...

Страница 17: ...ess level electrically isolated Insulation resistance Insulation voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental condit...

Страница 18: ...V 80 AM 1kHz EN 61000 4 4 Burst degree of severity 3 EN 61000 4 5 Surge installation class 3 Due to the high energetic single pulses with Surge an appropriate external protective circuit with lightnin...

Страница 19: ...ng controls Touchscreen PCAP Touch function Dual Touch Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP MPI PROFIBUS DP connector Serial COM1 RS232 RS422 RS485 COM1 connecto...

Страница 20: ...nical data Housing Protection type Material coated aluminium steel plate Mounting via integrated pivoted lever Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 562 4 m...

Страница 21: ...mory 2 GB User memory 16 GB Available memory user data 7 GB SD MMC Slot CF Card Slot Typ II CFast Slot Time Real time clock buffered Clock buffered period min 4 y Type of buffering lithium battery Loa...

Страница 22: ...V Power supply permitted range DC 20 4 28 8 V Reverse polarity protection Current consumption no load operation 1 2 A Current consumption rated value 1 3 A Inrush current 1 3 A I t 0 35 A s Power loss...

Страница 23: ...kness 12 mm Weight 9 1 kg Environmental conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 75 C Certifications UL certification yes KC certification VIPA HMI Hardware description...

Страница 24: ...g tableau and control cabinet fronts the Panel PC requires the following front panel cutting Panel PC W x H in mm 67S PNL0 547 x 367mm The material thickness of the installation cut out is 3 12mm For...

Страница 25: ...ulling the plate 2 With the label facing up insert the CFast card until it is com pletely seated in the slot and reinstall the cover plate After installation the CFast card is automatically recognized...

Страница 26: ...l PC is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on the initial screen w...

Страница 27: ...under www vipa com in the download area 1 Insert the USB stick into USB port of the Panel PC and connect the keyboard 2 Click Search Image The images found will be listed This may take a few sec onds...

Страница 28: ...and 5 seconds are default n Via Rotation the orientation of the panel can be changed n Via Program Start with you can add programmes which have to start automatically 1 Select Start and assign a name...

Страница 29: ...rt screen of the VIPA Startup Man ager 3 4 Connection to a PLC system n For the inclusion into your PLC system several HMI SCADA project engineering platforms are at your disposal that has to be insta...

Страница 30: ...re differentiated n Double click A double click has to be executed like mouse operation by touching the area at the screen twice A double click on an object opens res executes this n Drag By tapping o...

Страница 31: ...e following structure 1 Start button This button offers you access to all components of your Panel PC such as applications system settings file browser etc 2 Windows Explorer The Windows Explorer is s...

Страница 32: ...ware keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software key board is automatically shown At the moment the following keyboard...

Страница 33: ...bridge via Bridge Connections in the context menu A further Ethernet adapter called Network Bridge will be displayed Here you can make all settings n System properties Via Start Settings System and Se...

Страница 34: ...1 Type cmd under Start Run 2 In the next window type control userpasswords2 3 In the opening dialog window uncheck the box User must enter a user name and password to use this computer and confirm wi...

Страница 35: ...in the system tray 2 In the next window click on Configure 3 In the following window select enable under Pending command to enable the Enhanced Write Filter 4 Confirm with Apply and OK 5 To disable th...

Страница 36: ...ng the system clock n Redefining the communication ports to prevent any conflicts n Making changes to the power management configuration n Changing the password or making other changes to the security...

Страница 37: ...2 Load previous values F3 Load optimized default values F4 Saves and exits the setup program Enter Enters the highlighted submenu When 4 appears on the left of a particular field it indicates that a s...

Страница 38: ...plays hours from 00 to 23 n minute displays minutes from 00 to 59 n second displays seconds from 00 to 59 Displays the access level of the current user in the BIOS for example administrator 4 3 Advanc...

Страница 39: ...or disable hyper threading XD can prevent certain classes of malicious buffer overflow attacks Enabled Permit the switching on of the execute disable function by the OS Disabled Prevents the switching...

Страница 40: ...n is used to configure the IDE devices Enables or disables SATA controller Configures the SATA as IDE or AHCI mode IDE This option configures the serial ATA drives as parallel ATA physical storage dev...

Страница 41: ...t support EHCI hand off The EHCI ownership change should be claimed by the EHCI driver Selects the USB mass storage device s start unit command timeout 10 20 30 or 40 seconds This section is used to c...

Страница 42: ...le Selects an optimal setting for the super IO device This field is used to configure the mode of serial port 1 as RS232 RS422 default RS485 or RS485 AUTO Enables or disables the terminal resistor for...

Страница 43: ...the chipset CAUTION Setting incorrect field values may cause the system to malfunction Display the memory information This section is used to configure the Intel IGD graphic configuration Host Bridge...

Страница 44: ...is Tact Switch Please configure this option only when changing the panel otherwise the display may not work The options are Tact Switch Manual and Light Sensor The default setting is Manual and the Ba...

Страница 45: ...timer System response when power returns after an AC power failure Last State The system will return to the state where you left off before power failure occurs Power Off The system s power is off You...

Страница 46: ...Disabled Displays normal POST messages Upon Request GA20 can be disabled using BIOS services Always Do not allow disabling GA20 this option is useful when any RT code is executed above 1MB This field...

Страница 47: ...inistrator rights Select this to reconfigure the administrator s password Your pass word must contain at least 3 characters and should be maximal 20 characters long Select this to reconfigure the user...

Страница 48: ...lity and reboot the system without saving the changes select this field then press Enter You may be prompted to confirm again before exiting The BIOS setup exits and a restart fol lows To save changes...

Страница 49: ...s Enter A dialog box will appear Confirm by selecting Yes To bypass the boot sequence from the boot option list and boot from a particular device select the desired device and press Enter To launch EF...

Страница 50: ...ironments and meets high demands on the EMC Neverthe less you should project an EMC planning before installing the compo nents and take conceivable interference causes into account Electromagnetic int...

Страница 51: ...the per sonnel n Contactors Inductive coupling Inductive or magnetic coupling occurs between two current active line loops The magnetic flows associated with the cur rents induct interference vol tag...

Страница 52: ...ow with the cabinet Use metallic or metallised plug cases for isolated data lines n In special use cases you should appoint special EMC actions Consider to wire all inductivities with erase links Plea...

Страница 53: ...rom corrosion e g with grease n Moveable grounding parts e g cubicle doors have to be con nected via flexible ground strips The ground strips should be short and have a large surface because the surfa...

Страница 54: ...applicable lightning pro tection and grounding regulations when installing exterior cables CAUTION Where cables and signal lines for PLC equipment are installed outside of buildings the conditions for...

Страница 55: ...orrosion n The equipotential bonding conductor should be installed in such a manner that it includes the smallest surface between the bonding conductor and the signal lines Screening is one method com...

Страница 56: ...en n Attach the screens to the screening rail directly at the point where the cables enter the enclosure The screening conductor must be continued to the module without interruption however it must no...

Страница 57: ...consist of incandescent lights e g LINESTRA lamps Avoid using fluorescent lamps as these lamps can cause interference If you can not avoid using fluorescent lamps you should implement the steps outli...

Страница 58: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunch...