background image

2 Kit Installation

YASKAWA

TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual

9

Figure 2.2 Frame 1 Conduit Knockout Dimensions

Table 2.2 Frame 1 Conduit Knockout Dimensions

Dimensions mm (in)

D

D1

W

W1

W2

W3

W4

W5

Ød2

Ød3

Ød4

54

(2.12)

147

(5.77)

62.3

(2.45)

53.3

(2.10)

60.3

(2.37)

65.8

(2.59)

57.8

(2.28)

33.6

(1.32)

50

(1.97)

44

(1.73)

35

(1.38)

Figure 2.3 Frame 2 Conduit Knockout Dimensions

Table 2.3 Frame 2 Conduit Knockout Dimensions

Dimensions mm (in)

D

D1

W

W1

W2

W3

W4

W5

Ød2

Ød3

Ød4

Ød5

48

(1.89)

157

(6.19)

94.5

(3.72)

68.1

(2.68)

34.1

(1.34)

67.8

(2.67)

72.3

(2.85)

119

(4.69)

50

(1.97)

44

(1.73)

35

(1.38)

62

(2.44)

W3

D1

D

W

Ød3

Ød2

Ød4

W1

W2

W1

W4

W5

106 [4.17]

305 [12.01]

max.10 [0.39]

max.10 [0.39]

119 [4.69]

72.3 [2.85]

67.8 [2.67]

68.1 [2.68]

94.5 [3.72]

34.1 [1.34]

157 [6.19]

48 [1.89]

Ø62 [Ø2.44]

(2) - Ø35 [Ø1.38]

Ø44 [Ø1.73]

(2) - Ø50 [Ø1.97]

100 [3.95]

65.8 [2.59]

53.3 [2.10]

57.8 [2.28]

147 [5.77]

54 [2.12]

33.6 [1.32]

53.3 [2.10]

62.3 [2.45]

60.3 [2.37]

(5) - Ø35 [Ø1.38]

Ø50 [Ø1.97]

Ø44 [Ø1.73]

D1

D

Ød5

Ød4

Ød3

Ød2

W

W1

W2

W3

W4

W5

Содержание UUX001686

Страница 1: ...rive Option Installation Manual Type UUX001686 UUX001687 UUX001703 Models 200 V class 20 to 60 HP 400 V class 30 to 125 HP To properly use the product read this manual thoroughly and retain for easy r...

Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual...

Страница 3: ...n Manual 3 Table of Contents 1 Preface and General Safety 4 General Description 4 Option Package Contents 4 Applicable Documentation 4 General Safety 5 2 Kit Installation 7 Section Safety 7 Installati...

Страница 4: ...crew 4 ea USP04765 1 Applicable Documentation Document Description YASKAWA AC Drive Option UL Type 1 Kit for Single Phase Converter Installation Manual Read this manual before you install this option...

Страница 5: ...ING Sudden Movement Hazard System may start unexpectedly when the unit is energized resulting in death or serious injury Clear all personnel from the converter drive motor and machine area before ener...

Страница 6: ...e equipment if a fuse is blown or a Ground Fault Circuit Interrupter GFCI is tripped Repair the cause of the problem prior to re energizing the equipment Check the wiring and the selection of the peri...

Страница 7: ...ing the converter inside an enclosed panel or cabinet When multiple drives are placed inside the same enclosure panel install proper cooling to ensure air entering the enclosure does not exceed 40 C F...

Страница 8: ...xterior and Mounting Dimensions Table 2 1 UL Type 1 Kit Mounting Dimensions SPC Model Kit Number Knockout Dimension Figure Dimensions mm in W H D D1 H1 H2 2015 2022 4022 4030 UUX001686 Figure 2 2 256...

Страница 9: ...2 50 1 97 44 1 73 35 1 38 Figure 2 3 Frame 2 Conduit Knockout Dimensions Table 2 3 Frame 2 Conduit Knockout Dimensions Dimensions mm in D D1 W W1 W2 W3 W4 W5 d2 d3 d4 d5 48 1 89 157 6 19 94 5 3 72 68...

Страница 10: ...in D D1 D2 W W1 W2 W3 d3 d4 d5 79 3 11 155 6 09 106 4 17 75 2 95 65 2 56 22 3 0 88 90 3 54 50 1 97 35 1 38 62 2 44 Figure 2 5 Frame 3B Conduit Knockout Dimensions Table 2 5 Frame 3B Conduit Knockout D...

Страница 11: ...ded M4 x 10 captive pan head screws to attach the top cover Tighten the screws to a tightening torque of 0 98 to 1 33 N m 8 67 to 11 77 in lb Figure 2 6 Attach the Top Cover 4 Remove the two bottom li...

Страница 12: ...67 to 11 77 in lb Note Kit UUX001783 ships with two heatsink covers Use the information in Table 2 6 to select the correct cover The part number is stamped on the part for identification You can disc...

Страница 13: ...the screws to a tightening torque of 3 92 to 4 90 N m 34 69 to 43 37 in lb Figure 2 9 Attach the Bottom Housing 7 Remove the necessary conduit knockouts To remove a conduit knockout insert the tip of...

Страница 14: ...to the manual packaged with the SPC for wiring instructions Figure 2 11 Wire the SPC 9 Use the provided M4 x 10 truss head screws to attach the bottom cover Tighten the screws to a tightening torque o...

Страница 15: ...ion YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual 15 10 The kit installation is complete and the SPC is now enclosed in a UL Type 1 enclosure Figure 2 13 Installati...

Страница 16: ...16 YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual Revision History Date of Publication Revision Number Section Revised Content February 2019 First Edition...

Страница 17: ...YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual 17...

Страница 18: ...reign Trade Regulations Therefore be sure to follow all procedures and submit all relevant documentation according to any and all rules regulations and laws that may apply Specifications are subject t...

Отзывы: