8.3 Connecting Peripheral Devices
8.3 Connecting Peripheral Devices
illustrate how to configure the drive and motor to operate with various peripheral devices.
For more detailed instructions on how to install each device shown below, refer to the specific manual for that device.
Note:
Note that if the drive is set to trigger a fault output whenever the fault restart function is activated (L5-02 = 1), then a sequence to
interrupt power when a fault occurs will result in shutting off the power to the drive as the drive attempts to restart itself. The
default setting for L5-02 is 0 (fault output active during restart attempt).
◆
CIMR-U
2
0028 to 2
0248, CIMR-U
4
0011 to 4
0590
Figure 8.1
Figure 8.1 Connecting Peripheral Devices (CIMR-U
2
0028)
Cop
y
Ver
ify
Re
ad
LOCK
YA
S
K
A
W
A
JVOP-181
USB Copy Unit
COM
ERR
Power
Supply
Surge
Absorber
LED Operator/LCD Operator
Engineering Software Tools
USB
Copy unit
Ground
Ground
Motor
Magnetic
Contactor
(switches to
line power)
USB Cable
(Type-AB)
USB Cable
(Type-AB, sold separately)
PC
Momentary
Power Loss
Recovery Unit
Line
Breaker
(MCCB)
or
Leakage
Breaker
Magnetic
Contactor
(MC)
Zero-phase
Reactor
U1000
U/T1 V/T2 W/T3
R/L1
n1
p1
N
B1/P
S/L2 T/L3
DriveWizard
DriveWorksEZ