5.1 A: Initialization
178
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
Forward run, Reverse run command for 2-wire sequence on page 273
Setting 3330: 3-Wire Initialization
The drive parameters are returned to factory default values with digital inputs S1, S2, and S5 configured as Run, Stop,
and Forward/Reverse respectively. Also refer to digital input functions,
Setting 0: 3-Wire Sequence on page 266
Setting 5550: oPE04 Reset
If parameters on a certain drive have been edited and then a different terminal block is installed with different settings
saved in its built-in memory, an oPE04 error will appear on the display. To use the parameter settings saved to the
terminal block memory, set A1-03 to 5550.
Notes on Parameter Initialization
will not be reset when the drive is initialized by setting A1-03 = 2220 or 3330.
Although the control mode in A1-02 is not reset when A1-03 is set to 2220 or 3330, it may change when an application
preset is selected.
Table 5.1 Parameters not Changed by Drive Initialization
■
A1-04, A1-05: Password and Password Setting
A1-04 is for entering the password when the drive is locked. A1-05 is a hidden parameter used to set the password.
How to use the Password
The user can set a password for the drive to restrict access. The password is set to A1-05 and must be entered to A1-04 to
unlock parameter access. Until the correct password is entered, the following parameters cannot be viewed or edited:
A1-01, A1-02, A1-03, A1-06, A1-07, and A2-01 through A2-32.
The instructions below demonstrate how to set a new password. Here, the password set is “1234”. An explanation
follows on how to enter the password to unlock the parameters.
Table 5.2 Setting the Password for Parameter Lock
No.
Parameter Name
A1-00
Language Selection
A1-02
Control Method Selection
E1-03
V/f Pattern Selection
E5-01
Motor Code Selection (for PM motors)
E5-02
Motor Rated Power (for PM Motor)
E5-03
Motor Rated Current (for PM Motor)
E5-04
Number of Motor Poles (for PM Motor)
E5-05
Motor Stator Resistance (r1) (for PM Motor)
E5-06
Motor d-Axis Inductance (Ld) (for PM Motor)
E5-07
Motor q-Axis Inductance (Lq) (for PM Motor)
E5-09
Motor Induction Voltage Constant 1 (Ke) (for PM Motor)
E5-24
Motor Induction Voltage Constant 2 (Ke) (for PM Motor)
F6-
/F7-
Communication parameters (initialized when F6-08 = 1)
L8-35
Installation Method Selection
o2-04
Drive Model Selection
No.
Parameter Name
Setting Range
Default
A1-04
Password
0000 to 9999
0000
A1-05
Password Setting
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key until the Parameter Setting Mode screen appears.
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (AI)
Rdy
JOG
FWD
RSEQ
RREF
HELP
- MODE -
PRG
DATA
Programming
FWD
SIEP_C710636_02B_1_0.book 178 ページ 2015年11月25日 水曜日 午後4時56分