background image

The listing command for all network connections of your Touch Panel

is \> 

net use

You can terminate already assigned network resources via
\> 

net use local_name /d

Example: \> 

net use data /d

 deletes the network connection to

the drive "archive" of "test server".

To save the settings also after power on, you have to store

them to the registry with ‘START 

è

 Programs

è

 KuK_Tools 

è

 KuK Tools’ [Store].

List network connec-

tions

Terminate network con-

nections

VIPA HMI

Deployment Touch Panel

Access to the network resources

HB160 | TP | 62G-FID0 | GB | 15-36

 

44

Содержание TP 606C

Страница 1: ...TP 62G FID0 Manual HB160 TP 62G FID0 GB 15 36 VIPA HMI Touch Panel TP 606C...

Страница 2: ...62G FID0_000_TP606C 1 GB 2015 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Страница 3: ...5 3 3 Connection to a PLC system 29 3 4 Operating system Windows Embedded CE 6 0 Prof 29 3 4 1 General 29 3 4 2 Structure 31 3 5 Communication via ActiveSync 35 3 6 Integrated Server 37 3 6 1 General...

Страница 4: ...com Every effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing Nevertheless the authors retain the right to modify the in...

Страница 5: ...s VIPA GmbH Ohmstra e 4 91074 Herzogenaurach Germany Telefax 49 9132 744 1204 EMail documentation vipa de Contact your local VIPA Customer Service Organization representa tive if you encounter problem...

Страница 6: ...3 Safety information The Touch Panels are constructed and produced for n VIPA CPUs 01x 11x 21x 31x 51x and S7 300 400 from Sie mens n communication and process control n industrial applications n oper...

Страница 7: ...e carried out when the system has been disconnected from power Installation and hardware modifications only by prop erly trained personnel The national rules and regulations of the respective country...

Страница 8: ...les that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the conse quent implementation of protection devices...

Страница 9: ...ytes n Processor Xscale 1 1GHz n Work memory 256Mbyte n User memory 512Mbyte n 380Mbyte memory for user data n CF Card II and MMC SD card slot n RS232 RS422 485 MPI PROFIBUS DP slave Ethernet USB A an...

Страница 10: ...2 MMC SD 1 RS422 485 interface COM 2 2 RS232 interface COM 1 3 MPI PROFIBUS DP RS485 interface 4 Host USB A interface 5 Slave USB B interface 6 RJ45 jack for Ethernet communication 7 Slot for DC 24V...

Страница 11: ...fferences between the 4 cores n Serial bus connection in 4 wire technology using full duplex mode n Data communications up to a max distance of 500m n Data communication rate up to 115 2kBaud n Serial...

Страница 12: ...SB A interface USB mouse keyboard stick or USB hard discs can be connected For project transfer with Microsoft ActiveSync a programming cable can be connected using the Slave USB B interface The USB A...

Страница 13: ...e KuK Tools within consignment As internal permanent storage medium every Touch Panel has a flash disc with a size of 512Mbyte about 380Mbyte user data After the start of Windows CE this memory is lis...

Страница 14: ...hen plugging the security flap additionally snaps into position above the plugged memory card 2 4 Dimensions For the installation of the Touch Panel in control cabinets and desks the following dimensi...

Страница 15: ...mounting cut out 2 5 6mm The deviation from the plane for the panel cut out is 0 5mm This condition must be fulfilled for the mounted HMI device Permissible surface roughness in the area of the seal...

Страница 16: ...he process level electrically isolated Insulation resistance Insulation voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental...

Страница 17: ...10V 80 AM 1kHz EN 61000 4 4 Burst degree of severity 3 EN 61000 4 5 Surge installation class 3 Due to the high energetic single pulses with Surge an appropriate external protective circuit with lightn...

Страница 18: ...ting controls Touchscreen resistive Touch function Single Touch Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP RS485 isolated MPI PROFIBUS DP connector Sub D 9 pin female...

Страница 19: ...al data Housing Protection type Material die cast aluminum Mounting via integrated pivoted lever Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 212 mm x 156 mm x 7 5...

Страница 20: ...e memory user data 380 MB SD MMC Slot CF Card Slot Typ II CFast Slot Time Real time clock buffered Clock buffered period min 6 w Type of buffering Vanadium Rechargeable Lithium Battery Load time for 5...

Страница 21: ...r supply permitted range DC 20 4 28 8 V Reverse polarity protection Current consumption no load operation 0 34 A Current consumption rated value 0 5 A Inrush current 6 A I t 0 2 A s Power loss 8 2 W S...

Страница 22: ...thickness 6 mm Weight 1614 g Environmental conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 60 C Certifications UL certification in preparation VIPA HMI Hardware description T...

Страница 23: ...cabinet fronts the Touch Panel requires the following front plate cutting Touch Panel W x H in mm 62G FID0 200 x 144 The fixing technique is integrated in the casing of the Touch Panel and accessible...

Страница 24: ...rs to the CageClamps like this 1 Round opening for wires 2 Locking orange for screwdriver 3 Test point for 2mm test tip The picture on the left side shows the cabling step by step from top view 1 For...

Страница 25: ...as the Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears There is a button on the init...

Страница 26: ...list of all the firmware images is shown which are available on the panel and connected storage media These images will be listed with create data and version number Choose your new image If the sele...

Страница 27: ...the following batch files n Start VIPA Webbrowser bat n Start VIPA Webserver and Browser fullscreen bat n Start VIPA Webserver and Browser bat n Start VIPA Webserver bat Under Delay Time you can adju...

Страница 28: ...e registry set tings for the backlight the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and th...

Страница 29: ...communicates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically...

Страница 30: ...y tapping on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the drag ging that selects the touched objects Characteristics with Window...

Страница 31: ...our Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no button for minimizing The switch...

Страница 32: ...allows you to select one of the available software key boards At the moment the following standard keyboards are imple mented At pushed Shift key At pushed a key Please note that can exclusively be en...

Страница 33: ...e keyboard allows you to enter key entries without con necting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides the keyboard aga...

Страница 34: ...can be found in Start Settings Network and Dial up Connections The default setting is address assignment via DHCP n System properties System Here you receive information about the version of the curre...

Страница 35: ...Tools 3 5 Communication via ActiveSync ActiveSync is a communication platform developed by Microsoft especially for mobile computers to synchronize data between a mobile device and a PC via USB Many...

Страница 36: ...h 1 Connect your Touch Panel via the Device USB B jack to your PC and turn on the Touch Panel The USB device Touch Panel is recognized and the dialog window new partnership opens 2 Choose yes for fixi...

Страница 37: ...uch Panel has several integrated server that enable a remote maintenance within a network Some servers only allow access by means of entering User name and Password The following login data are used s...

Страница 38: ...llowing condi tions for a ftp connection If there are still problems with the ftp access please ask your system administrator Internet Explorer n ftp access possible with version 5 5 or higher n activ...

Страница 39: ...uch Panel with attached Admin type Using the websites you may e g publish online documentations for a connected PC or go online with applications on the PC As web admin you have access to all function...

Страница 40: ...llowing into the address bar telnet IP address When the connection is established the Panel PC asks for the user name and the password 2 Enter the following Login wince Password vipatp entry is hidden...

Страница 41: ...the VNC server is on delivery deactivated Due to software reasons VIPA does not support the VNC server function With Autostart you can select the automatic startup of the VNC server via the Startup M...

Страница 42: ...sources in a Micro soft network like drives and printer Here you may assign existing public directories or printer in the network to local directories or printer in the Touch Panel Condition for this...

Страница 43: ...Local_Name data network drive testserver archive User name guest Input net use data testserver archiv user guest The connected network drive is then available via network data at the Touch Panel The c...

Страница 44: ...le net use data d deletes the network connection to the drive archive of test server To save the settings also after power on you have to store them to the registry with START Programs KuK_Tools KuK T...

Страница 45: ...vironments and meets high demands on the EMC Neverthe less you should project an EMC planning before installing the compo nents and take conceivable interference causes into account Electromagnetic in...

Страница 46: ...the per sonnel n Contactors Inductive coupling Inductive or magnetic coupling occurs between two current active line loops The magnetic flows associated with the cur rents induct interference vol tag...

Страница 47: ...ow with the cabinet Use metallic or metallised plug cases for isolated data lines n In special use cases you should appoint special EMC actions Consider to wire all inductivities with erase links Plea...

Страница 48: ...from corrosion e g with grease n Moveable grounding parts e g cubicle doors have to be con nected via flexible ground strips The ground strips should be short and have a large surface because the surf...

Страница 49: ...applicable lightning pro tection and grounding regulations when installing exterior cables CAUTION Where cables and signal lines for PLC equipment are installed outside of buildings the conditions for...

Страница 50: ...corrosion n The equipotential bonding conductor should be installed in such a manner that it includes the smallest surface between the bonding conductor and the signal lines Screening is one method co...

Страница 51: ...een n Attach the screens to the screening rail directly at the point where the cables enter the enclosure The screening conductor must be continued to the module without interruption however it must n...

Страница 52: ...d consist of incandescent lights e g LINESTRA lamps Avoid using fluorescent lamps as these lamps can cause interference If you can not avoid using fluorescent lamps you should implement the steps outl...

Страница 53: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunc...