7.4 Drive Cooling Fans
7.4 Drive Cooling Fans
NOTICE:
Follow cooling fan replacement instructions. The cooling fan cannot operate properly when installed incorrectly and could
seriously damage the drive. To ensure maximum useful product life, replace all cooling fans when performing maintenance.
Contact your Yaskawa representative or supplier to order replacement cooling fans as required.
Some drive models have multiple cooling fans.
For drives with multiple cooling fans, replace all the fans when performing maintenance to ensure maximum useful
product life.
Table 7.6 Number of Cooling Fan
Note:
Finless- drive models (CIMR-T
BV0001J to BV0012J, 2V0001J to 2V0056J, 2V0069L, and 4V0001J to 4V0038J) do not have
a cooling fan.
◆
Cooling Fan Replacement
The cooling fan is installed on the top of the drive. The cooling fan can easily be replaced without tools or removal of the
drive or enclosure parts.
WARNING!
Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after
the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric
shock, wait at least five minutes after all indicators are OFF and measure the DC bus voltage level to confirm safe level.
CAUTION!
Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or moderate injury. Shut off the
power to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled
down.
Single-Phase 200 V
Three-Phase 200 V
Three-Phase 400 V
CIMR-T
Cooling Fan
CIMR-T
Cooling Fan
CIMR-T
Cooling Fan
BV0001B
–
2V0001B
–
4V0001B
–
BV0002B
–
2V0002B
–
4V0002B
–
BV0003B
–
2V0004B
–
4V0004B
–
BV0006B
–
2V0006B
1
4V0005B
1
BV0010B
1
2V0010B
1
4V0007B
1
BV0012B
1
2V0012B
1
4V0009B
1
–
–
2V0020B
1
4V0011B
1
–
–
2V0030B
2
4V0018B
2
–
–
2V0040B
2
4V0023B
2
–
–
2V0056B
2
4V0031B
2
–
–
2V0069A
2
4V0038B
2
Содержание T1000V
Страница 10: ...10 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 30: ...1 4 Component Names 30 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 44: ...2 2 Mechanical Installation 44 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 100: ...4 10 Test Run Checklist 100 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 232: ...5 12 U Monitor Parameters 232 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 280: ...6 9 Troubleshooting without Fault Display 280 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 294: ...7 5 Drive Replacement 294 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 306: ...8 5 Communication Options 306 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 316: ...A 6 Drive Derating Data 316 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 422: ...D 4 Safe Disable Input Precautions 422 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...