5.11 S: Functions for Textile Applications
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
227
P
a
ra
me
te
r D
eta
ils
5
■
S5-05: KEB Synchronous Acceleration Time
Sets time to accelerate from the frequency after KEB to the set frequency reference. This setting can be used to let
multiple drives accelerate synchronously back to the set speed after power loss.
Note:
If S5-05 is set to 0.0, the drive will use the normal acceleration times (C1-01, C1-03, C1-05, C1-07) to accelerate back up to
speed once power is restored.
■
S5-06: S-Curve at KEB Deceleration Start
Sets the S-curve time when KEB begins deceleration. Increase this setting if overvoltage trouble occurs.
Decreases if undervoltage occurs right after power loss deceleration.
■
S5-07: Frequency Gain at KEB Start during Constant Speed
Sets the output frequency reduction step applied when power loss is detected during constant speed operation and then
KEB starts.
Percent of frequency reduction = (slip frequency just before KEB)
×
S5-07
×
2
Increases if Uv is detected right after power loss deceleration.
■
S5-08: Frequency Gain at KEB Start during Acceleration
Sets the output frequency reduction step applied when power loss is detected during acceleration and then KEB starts.
Percent of frequency reduction = (slip frequency just before KEB)
×
S5-08
×
2
■
S5-09: Frequency Gain at KEB Start during Deceleration
Sets the output frequency reduction step applied when power loss is detected during deceleration and then KEB starts.
Percent of frequency reduction = (slip frequency just before KEB)
×
S5-09
×
2
■
S5-10: Synchronous Deceleration ov Prevention
Enables or disables overvoltage prevention during synchronous KEB operation (S4-01 = 2). If S5-10 is enabled the drive
will temporary halt the deceleration if the DC bus voltage rises too high in order to avoid overvoltage trips.
0: Disabled (requires a braking option)
1: Enabled
No.
Name
Setting Range
Default
S5-05
KEB Synchronous Acceleration Time
0.0 to 200.0 s
0.0 s
No.
Name
Setting Range
Default
S5-06
S-Curve at KEB Deceleration Start
0.00 to 2.50 s
0.20 s
No.
Name
Setting Range
Default
S5-07
Frequency Gain at KEB Start during Constant Speed
0 to 300%
100%
No.
Name
Setting Range
Default
S5-08
Frequency Gain at KEB Start during Acceleration
0 to 300%
100%
No.
Name
Setting Range
Default
S5-09
Frequency Gain at KEB Start during Deceleration
0 to 300%
100%
No.
Name
Setting Range
Default
S5-10
Synchronous Deceleration ov Prevention
0, 1
0
Содержание T1000V
Страница 10: ...10 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 30: ...1 4 Component Names 30 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 44: ...2 2 Mechanical Installation 44 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 100: ...4 10 Test Run Checklist 100 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 232: ...5 12 U Monitor Parameters 232 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 280: ...6 9 Troubleshooting without Fault Display 280 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 294: ...7 5 Drive Replacement 294 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 306: ...8 5 Communication Options 306 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 316: ...A 6 Drive Derating Data 316 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 422: ...D 4 Safe Disable Input Precautions 422 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...