5.4 d: Reference Settings
144
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Multi-Step Speed Selection
Depending on how many speeds are used, some digital inputs have to be programmed for Multi-Step Speed Selection 1,
2, and 3 (H1-
= 3, 4, 5). For the Jog reference a digital input must be set to H1-
= 6.
Notes on using analog inputs as multi-speed 1 and 2:
• If the frequency reference source is assigned to analog input A1 (b1-01 = 1), then this input will be used for Frequency
Reference 1 instead of d1-01. If the reference source is assigned to the digital operator (b1-01 = 0), then d1-01 will be
used as Frequency Reference 1.
• When the analog input A2 function is set to “Auxiliary Frequency” (H3-10 = 2), then the value input to terminal A2
will be used as the Multi-Step Speed 2 instead of the value set to parameter d1-02. When H3-10 does not equal 2, then
d1-02 becomes the reference for Multi-Step Speed 2.
The different speed references can be selected as shown in
illustrates the multi-step speed
selection.
Table 5.14 Multi-Step Speed Reference and Terminal Switch Combinations
Figure 5.30
Figure 5.30 Preset Reference Timing Diagram
Reference
<1> The Jog frequency overrides the frequency reference being used.
Multi-Step
Speed
H1-
=3
Multi-Step
Speed 2
H1-
=4
Multi-Step
Speed 3
H1-
=5
Jog Reference
H1-
=6
Frequency Reference 1 (d1-01/A1)
OFF
OFF
OFF
OFF
Frequency Reference 2 (d1-02/A2)
ON
OFF
OFF
OFF
Frequency Reference 3 (d1-03)
OFF
ON
OFF
OFF
Frequency Reference 4 (d1-04)
ON
ON
OFF
OFF
Frequency Reference 5 (d1-05)
OFF
OFF
ON
OFF
Frequency Reference 6 (d1-06)
ON
OFF
ON
OFF
Frequency Reference 7 (d1-07)
OFF
ON
ON
OFF
Frequency Reference 8 (d1-08)
ON
ON
ON
OFF
Jog Frequency Reference (d1-17)
−
−
−
ON
Multi-step Speed Ref. 2
Multi-step Speed Ref. 3
Jog Reference
Multi-step Speed Ref. 1
Frequency
reference
Time
d1-04
d1-01
(A1)
d1-02
(A2)
d1-03
ON
ON
ON
ON
ON
d1-05
d1-06
d1-07
d1-17
ON
ON
ON
ON
d1-08
FWD (REV) Run/Stop
Содержание T1000V
Страница 10: ...10 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 30: ...1 4 Component Names 30 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 44: ...2 2 Mechanical Installation 44 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 100: ...4 10 Test Run Checklist 100 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 232: ...5 12 U Monitor Parameters 232 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 280: ...6 9 Troubleshooting without Fault Display 280 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 294: ...7 5 Drive Replacement 294 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 306: ...8 5 Communication Options 306 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 316: ...A 6 Drive Derating Data 316 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 422: ...D 4 Safe Disable Input Precautions 422 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...