Installation and Operation Guide SOLECTRIA XGI 1500 (Rev E, 5 Mar. 2021)
52 of 70
Communication Commissioning
Once all inverters are installed and energized, the XGI communications can be commissioned. Before
proceeding ensure that the following conditions are met:
All inverters energized, (DC voltage)
All inverters are connected via Ethernet in a supported network topology
All gateway inverters are connected to the LAN with DCHP enabled
Internet access is available on the LAN (if applicable)
Communication Commissioning Checklist
Connect to the Cluster
Connect to the desired Cluster over Ethernet or WiFi using a smart device. If connecting over Ethernet
be sure not to disrupt the daisy chain or star network, always connect to an inverter at the end of a
chain.
Verify Communication
On the Landing Page, verify that all expected inverters appear on the Inverter List. If inverters are
missing, check wiring and ensure that all inverters have been powered on for a minimum of 10 minutes.
Startup Wizard
Run the
Startup Wizard
by logging into one of the inverters and selecting
Startup Wizard
from the
main menu.
Name the Inverters
Enter a name for each inverter on the list.
Configure the Reference List
Add
or
Remove
the inverters from the reference list. This list consists of all inverters that are currently
communicating in the Cluster AND inverters that were previously added to the Reference List.
Select the Time Zone
Select the desired Time Zone from the dropdown list.
Choose a Cluster Name, SSID
A Cluster Name or SSID consists of three parts; the Site Name, Cluster ID, and WiFi channel. The
Cluster Name generated in this step will determine the WiFi SSID or WiFi network name.
INFO
✔
✔
✔
✔
Don’t Break the Chain!
When connecting to a Cluster over Ethernet during the commissioning process it is
important that the Cluster LAN remain intact. Always connect to an open port on one of the XGI inverters at
the end of a daisy chain as not to disconnect any inverters from the Cluster.
INFO
✔
✔
✔
✔
Discovery:
When inverters are connected in a Cluster it may take up to 10 minutes for all inverters to
discover each other.