SIEP C730600 23B V1000 Option PROFIBUS-DP Technical Manual
8 Parameter Process Data Object Formats
8
Parameter Process Data Object Formats
Supported Parameter Process Data Object (PPO) Type Formats
Set drive parameter F6-32 = “0” to use PPO type formats. The PPO is defined for cyclic data transfer, allowing the
master and the slave to exchange process data (PZD) and parameters. Refer to the PROFIBUS specification for more
information on PPO types 1~5.
SI-P3/V supports five possible PPO type formats:
All PPO Types have the registers STW, ZSW, HSW, and HIW. These registers are not mapped directly to drive registers.
Configuration of Registers
PKE
PPO type 1 (8 octets PKW + 4 octets PZD)
PPO type 2 (8 octets PKW + 12 octets PZD)
PPO type 3 (4 octets PZD)
PPO type 4 (12 octets PZD)
PPO type 5 (8 octets PKW + 20 octets PZD)
Bit
PPO Write
PPO Read
0
PNU number (
1
2
3
4
5
6
7
8
9
10
11
SPM always 0
SPM always 0
12
See Task ID
See Response ID
When Response ID is 7, see PWE error code
13
14
15
PPO TYPE 5: Octet-String 28
PPO TYPE 4: Octet-String 12
PPO TYPE 3: Octet-String 4
PPO TYPE 2: Octet-String 20
PKW: Parameter ID/value
PZD: Process Data, cyclically transferred
PKE: Parameter ID (1st and 2nd octet)
IND: Sub-index (3rd octet), 4th octet is reserved
PWE: Parameter value (5th until 8th octet)
STW: Control word
HSW: Main setpoint
ZSW: Status word
HIW: Main actual value
PPO TYPE 1: Octet-String 12
PKW
PZD
PKE
IND
PWE
PZD3 PZD4 PZD5 PZD6 PZD7 PZD8 PZD9 PZD10
PZD1
STW
ZSW
PZD2
HSW
HIW