26
YASKAWA
SIEP C730600 84G DeviceNet Technical Manual
1.
Prepare the communication cables as shown in
.
A - Sheath
B - Shield
C - Use electrical tape or shrink tubing to insulate
the cable.
D - Shield
Figure 5.23 Prepare Ends of Shielded Cable
2.
Connect the communication cables to the terminal block as shown in
When you attach the CN1 connector plug on the terminal block to the socket, make sure that you tighten
the screws on the left and right sides of the plug.
Tighten the screw to a correct tightening torque:
• 0.5 N
∙
m to 0.6 N
∙
m (4.4 in
∙
lb to 5.3 in
∙
lb)
3.
Make sure that you correctly connect the wires and that you did not accidentally pinch wire insulation in
the terminals.
Trim any frayed wires.
WARNING
Fire Hazard. Tighten all terminal screws to the correct tightening torque. Connections that are too
loose or too tight can cause incorrect operation and damage to the drive. Incorrect connections can also cause death
or serious injury from fire.
NOTICE
Do not let wire shields touch other signal lines or equipment. Insulate the wire shields with electrical
tape or shrink tubing. If you do not insulate the wire shields, it can cause a short circuit and damage the drive.
A - Pull back the shielding and lightly twist the end
with your fingers to keep the ends from fraying.
B - When you do not use crimp ferrules, remove
approximately 5.5 mm (0.21 in) of the covering
at the end of the wire.
C - Blade thickness of 0.4 mm (0.01 in) or less
D - Up to 2.5 mm
E - Tightening torque: 0.5 N
∙
m to 0.6 N
∙
m (4.4 in
∙
lb
to 5.3 in
∙
lb)
F - Terminal block CN1
G - DeviceNet Communication Cable (do not solder
ends)
H - Loosen the screws and put the wire into the
opening on the terminal block.
Figure 5.24 Communication Cable Wiring
◆
Termination Resistor Connection
Only connect network termination resistors (121 Ω, ±1%, 1/4 W) to nodes of the two ends of trunk line. Refer to
the ODVA website (www.odva.org) for more information on network cabling.
◆
Option MAC ID
■
Parameter F6-50 [DeviceNet MAC Address] (MAC ID Setting)
Setting range: 0 - 64