44
YASKAWA
TOEP C730600 89B PROFINET Installation Manual
No.
(Hex.)
Name
Description
Default
(Range)
F6-15
(0B5B)
Comm. Option
Parameters
Reload
Sets how the drive will enable the
F6-xx/F7-xx
communication-related parameters that you changed.
0 : Reload at Next Power Cycle
1 : Reload Now
2 : Cancel Reload Request
Note:
•
F6-15
is reset to
0
after setting
1
or
2
.
•
Not available on 1000-series drives.
0
(0 - 2)
F7-01
(03E5)
IP Address 1
Sets the static/fixed IP address. Sets the most significant octet.
Note:
•
This parameter is only effective when
F7-13 = 0
[Address Mode at Startup = Static]
.
•
All IP Addresses must be unique.
•
You must cycle power to the drive for the changes to
take effect. For non-1000 series drives, you can set
F6-
15 = 1 [Comm. Option Parameters Reload = Reload
Now]
.
192
(0 - 255)
F7-02
(03E6)
IP Address 2
Sets the static/fixed IP address. Sets the second most
significant octet.
Note:
•
This parameter is only effective when
F7-13 = 0
[Address Mode at Startup = Static]
.
•
All IP Addresses must be unique.
•
You must cycle power to the drive for the changes to
take effect. For non-1000 series drives, you can set
F6-
15 = 1 [Comm. Option Parameters Reload = Reload
Now]
.
168
(0 - 255)
F7-03
(03E7)
IP Address 3
Sets the static/fixed IP address. Sets the third most significant
octet.
Note:
•
This parameter is only effective when
F7-13 = 0
[Address Mode at Startup = Static]
.
•
All IP Addresses must be unique.
•
You must cycle power to the drive for the changes to
take effect. For non-1000 series drives, you can set
F6-
15 = 1 [Comm. Option Parameters Reload = Reload
Now]
.
1
(0 - 255)
F7-04
(03E8)
IP Address 4
Sets the static/fixed IP address. Sets the fourth most significant
octet.
Note:
•
This parameter is only effective when
F7-13 = 0
[Address Mode at Startup = Static]
.
•
All IP Addresses must be unique.
•
You must cycle power to the drive for the changes to
take effect. For non-1000 series drives, you can set
F6-
20
(0 - 255)