10 CC-Link Code Numbers
YASKAWA ELECTRIC
SIEP C730600 22C V1000 Option CC-Link Technical Manual
31
Monitor Codes
Table 22 Monitor Codes
Monitor Code
Name
Comments
0000H
Reserved
0001H
Output frequency
Units are determined by o1-03.
0002H
Output current
Units are either 0.1 A or 0.01 A, depending on the capacity of the drive.
0003H
Output voltage reference
Units: 0.1 V
0004H
Reserved
0005H
Frequency reference
Units are determined by o1-03.
0006H
Motor speed
Units: 1 min
-1
0007H
Motor torque
Units: 0.1%
0008H
DC bus voltage
Units: 1 V
0009H
Reserved
000AH
Reserved
000BH
Reserved
000CH
Reserved
000DH
Reserved
000EH
Output power
Units: 0.1 kW
000FH
Input terminal status
0010H
Output terminal status
0011H
Reserved
0012H
Motor excitation current
Units: 0.1%
0013H
Reserved
0014H
Cumulative operation time
• Units: 1 hour
• Parameter o4-02 determines if the operation time is the considered to be whenever the drive powered on or
only when there is voltage output.
0015H
Reserved
0016H
Reserved
0017H
Actual operation time
• Units: 1 hour
• Parameter o4-02 determines if the operation time is the considered to be whenever the drive powered on or
only when there is voltage output.
0018H
Motor secondary current
0019H
Reserved
0034H
PID setpoint
Units: 0.1%
0035H
PID input
Units: 0.1%
0036H
PID output
Units: 0.1%
1000H
Reserved
1001H
Reserved
1002H
Cumulative operation time
1003H
Watt-hour output (lower digits)
1004H
Watt-hour output (upper digits)
1010H
Alarm code
1011H
Fault code
1012H
Reserved
1013H
Fault contents 1
1014H
Fault contents 2
1015H
Fault contents 3
1016H
Fault contents 4
1017H
Fault contents 5
7
6
5
4
3
2
1
0
Multi-Function Digital Input 1 (terminal S1 enabled)
Multi-Function Digital Input 2 (terminal S2 enabled)
Multi-Function Digital Input 3 (terminal S3 enabled)
Multi-Function Digital Input 4 (terminal S4 enabled)
Multi-Function Digital Input 5 (terminal S5 enabled)
Multi-Function Digital Input 6 (terminal S6 enabled)
Multi-Function Digital Input 7 (terminal S7 enabled)
Not used
1: ON
RW
0: OFF
7
6
5
4
3
2
1
0
Multi-Function Digital Output (terminal MA/MB-MC) enabled
Multi-Function Digital Output 1 (terminal P1) enabled
Multi-Function Digital Output 2 (terminal P2) enabled
1: ON
RW
0: OFF
Not used
SIEP_C730600_22C_3_0.book 31 ページ 2022年8月23日 火曜日 午後1時4分