2.1 Ratings
2.1.1 Three-Phase, 200 VAC
2-2
2.1
Ratings
The ratings of the FT82 and FT83 SERVOPACKs are the same. This section gives the ratings of SERVOPACKs.
2.1.1
Three-Phase, 200 VAC
*
This is the net value at the rated load.
2.1.2
Single-Phase, 200 VAC
*
This is the net value at the rated load.
Model SGD7S-
2R8A
120A
Maximum Applicable Motor Capacity [kW]
0.4
1.5
Continuous Output Current [Arms]
2.8
11.6
Instantaneous Maximum Output Current [Arms]
9.3
28
Main
Circuit
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50
Hz/60 Hz
Input Current [Arms]
*
2.5
7.3
Control
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50
Hz/60 Hz
Input Current [Arms]
*
0.2
0.2
Power Supply Capacity [kVA]
*
1.0
3.2
Power Loss
*
Main Circuit Power Loss [W]
22.5
72.6
Control Circuit Power Loss [W]
12
15
Built-in Regenerative Resistor Power Loss [W]
−
10
Total Power Loss [W]
34.5
97.6
Regenerative
Resistor
Built-In Regenerative
Resistor
Resistance [
Ω
]
−
20
Capacity [W]
−
60
Minimum Allowable External Resistance [
Ω
]
40
20
Overvoltage Category
III
Model SGD7S-
2R8A
120A
Maximum Applicable Motor Capacity [kW]
0.4
1.5
Continuous Output Current [Arms]
2.8
11.6
Instantaneous Maximum Output Current [Arms]
9.3
28
Main Circuit
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50
Hz/60 Hz
Input Current [Arms]
*
5.0
16
Control
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50
Hz/60 Hz
Input Current [Arms]
*
0.2
0.25
Power Supply Capacity [kVA]
*
1.2
4.0
Power Loss
*
Main Circuit Power Loss [W]
23.7
71.8
Control Circuit Power Loss [W]
12
16
Built-in Regenerative Resistor Power Loss [W]
−
16
Total Power Loss [W]
35.7
103.8
Regenerative
Resistor
Built-In Regenerative
Resistor
Resistance [
Ω
]
−
12
Capacity [W]
−
60
Minimum Allowable External Resistance [
Ω
]
40
12
Overvoltage Category
III