1.3 Part Names
1-5
1
Outlin
e
Panel display
Indicates the servo status with a seven-segment
LED display.
–
Nameplate
Indicates the SERVOPACK model and ratings.
Located on the side of the SERVOPACK.
–
Input voltage
–
–
SERVOPACK model
Indicates the model number of the SERVOPACK.
1.6 Model Designations
Serial number
–
–
Dynamic brake unit
connector (CN115)
Used for ON/OFF control of the magnetic contac-
tor in the dynamic brake unit. Connect this con-
nector to terminals DBON and DB24 on the
dynamic brake unit.
–
Control power input
connectors
(CN103 and CN104)
Used to input 24 VDC (
±15%
). CN103 and
CN104 are equivalent inputs. It is normally not
necessary to connect CN104.
–
SERVOPACK-converter I/O
connector (CN901)
Connect this connector to CN901 on the converter. –
Charge indicator
Lights (orange) when the main circuit power sup-
ply is ON and stays lit as long as the internal
capacitor remains charged. Therefore, do not touch
the SERVOPACK even after the power supply is
turned OFF if the indicator is lit. It may result in
electric shock.
–
Main circuit DC voltage input
terminals (P and N)
Connect these terminals to P and N on the con-
verter.
–
Dynamic brake unit
connection terminals
(DU, DV, and DW)
Use these terminals to connect the dynamic brake
unit.
Do not connect servomotors to these terminals.
–
Ground terminal
Be sure to connect to protect against electrical
shock.
3.1 Main Circuit Wiring
Plunger
Do not use this plunger.
–
CN3 connector
Do not use this connector.
–
Communications LED
indicator (COM)
Lights green during local bus communications.
–
CN7 connector
Do not use this connector.
–
Local communications con-
nectors (CN6A and CN6B)
CN6A: Connect this connector to the multi-wind-
ing drive unit.
CN6B: Connect this connector to terminating
resistance.
–
I/O signal connector (CN1)
Used for sequence I/O signals.
3.3 I/O Signal Connections
Connector for safety function
devices (CN8)
Connect a safety function device.
Note: When not using the safety function, use the
SERVOPACK with the safety function’s
jumper connector (provided as an acces-
sory) inserted.
3.3.2 SERVOPACK Safety
Function Signal (CN8)
Names and Functions
5.11 Safety Function
CN2 connector
Do not use this connector.
–
+, - terminals
Do not connect anything to these terminals.
–
Servomotor terminals
(U, V, W)
Connect the main circuit cable (power line) for
servomotor.
3.1 Main Circuit Wiring
(cont’d)
No.
Name
Description
Reference