10.2 Operation of Digital Operator
10.2.2 Operation of Utility Functions
10-19
10
Appendice
s
JOG Speed Table Initialization (Fn065)
This function initializes JOG speed tables and restores the default settings.
Preparation
The following conditions must be met to initialize JOG speed tables.
•
The write-prohibited setting (Fn010) must not be set to write-protect parameters
.
•
A JOG speed table initialization must not be in progress for any means other than the digital
operator.
Operating Procedure
*
If the
key is pressed in an operation prohibited state, “Error.” is displayed for approximately 2 seconds and
then the display returns to the Fn065 operation screen. In this case, make the setting again by referring to
.
Step
Display after Operation
Keys
Operation
1
Press the
key to open the Utility Function
Mode main menu, and move the cursor with the
keys to select Fn065.
2
Press the
key to view the Fn065 operation
screen.
3
Press the
key to start JOG speed table ini-
tialization.
*
Do not turn OFF the control power supply until
initialization has been completed normally.
To cancel the Fn065 operation, press the
key before pressing the
key. The display
returns to the Utility Function Mode main menu
without executing the operation.
4
–
When JOG speed table initialization has been
completed normally, “Done.” is displayed.
5
Press the
key to return to the Utility Function
Mode main menu.