14.5 Manufacturer-Specific Objects
14-17
14
Object Dictionary
14.5
Manufacturer-Specific Objects
SERVOPACK Parameters (2000 Hex to 26FF Hex)
Objects 2000 hex to 26FF hex are mapped to SERVOPACK parameters (Pn
).
Object index 2
hex corresponds to Pn
in the SERVOPACK parameters (e.g., object
2100 hex is the same as Pn100).
User Parameter Configuration (2700 Hex)
This object enables all user parameter settings and initializes all of the position data.
If you change any of the following objects and restart operation without turning the power sup-
ply OFF and then ON again, you must execute this object to enable the new settings.
•
Objects 2701 hex, 2702 hex, 2703 hex, and 2704 hex
•
SERVOPACK parameters that require that the power supply be turned OFF and ON again to
enable changes to the parameter settings
Procedure
1.
Change the SERVOPACK to the Switch ON Disabled state.
2.
Set the new parameter settings.
3.
Set
user parameter configuration
(2700 hex) to 1. The parameter settings will be
enabled.
After execution, object 2700 hex will automatically be reset to 0.
Position User Unit (2701 Hex)
This object sets the user-defined position reference unit (Pos unit).
The user-defined position reference unit is calculated with the following formula.
1 [Pos unit] = (Numerator/Denominator) [inc]
Setting range: 1/4,096 < Numerator/Denominator < 65,536
(Alarm A.A20 will be detected if the setting exceeds the setting range.)
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
2700 hex
0
User parameter con-
figuration
UDINT
RW
No
0 to 0xFFFFFFFF
(default: 0)
No
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
2701 hex
0
Number of entries
USINT
RO
No
2
No
1
Numerator
UDINT
RW
No
1 to 1,073,741,823
(default: 1)
Yes
2
Denominator
UDINT
RW
No
1 to 1,073,741,823
(default: 1)
Yes