9.4 Monitoring Product Life
9.4.1 Items That You Can Monitor
9-9
9
Monitoring
9.4
Monitoring Product Life
9.4.1
Items That You Can Monitor
Monitor Item
Description
SERVOPACK Installa-
tion Environment
The operating status of the SERVOPACK in terms of the installation environment is
displayed.
Implement one or more of the following actions if the monitor value exceeds 100%.
•
Lower the surrounding temperature.
•
Decrease the load.
Servomotor Installation
Environment
The operating status of the Servomotor in terms of the installation environment is
displayed.
Implement one or more of the following actions if the monitor value exceeds 100%.
•
Lower the surrounding temperature.
•
Decrease the load.
Built-in Fan Service Life
Prediction
The unused status of the SERVOPACK is treated as the 100% value. The value
decreases based on the operating conditions, such as the time that the main circuit
power supply is ON. Use a monitor value of 0% as a guideline for the replacement
period. Refer to the following section for part replacement guidelines.
10.1.2 Guidelines for Part Replacement
Capacitor Service Life
Prediction
The unused status of the SERVOPACK is treated as the 100% value. The value
decreases based on the operating conditions, such as the time that the main circuit
power supply is ON. Use a monitor value of 0% as a guideline for the replacement
period. Refer to the following section for part replacement guidelines.
10.1.2 Guidelines for Part Replacement
Surge Prevention Cir-
cuit Service Life Predic-
tion
The unused status of the SERVOPACK is treated as the 100% value. The value
decreases each time the main circuit power supply is turned ON and each time the
servo is turned OFF. Use a monitor value of 0% as a guideline for the replacement
period. Refer to the following section for part replacement guidelines.
10.1.2 Guidelines for Part Replacement
Dynamic Brake Circuit
Service Life Prediction
The unused status of the SERVOPACK is treated as the 100% value. The value
decreases each time the main circuit power supply is turned ON and each time the
servo is turned OFF. Use a monitor value of 0% as a guideline for the replacement
period. Refer to the following section for part replacement guidelines.