5.1 Manipulating Parameters (Pn
)
5.1.5 Initializing Parameter Settings
5-10
Restrictions
If you prohibit writing parameter settings, you will no longer be able to execute some functions.
Refer to the following table.
*1.
An
Initialize
Button will be displayed in the Edit Parameters Dialog Box.
*2.
Refer to the following manual for details.
Σ
-7-Series
Σ
-7C SERVOPACK Troubleshooting Manual (Manual No.: SIEP S800002 07)
5.1.5
Initializing Parameter Settings
You can return the parameters to their default settings. You can specify the axis or axes to ini-
tialize.
Preparations
Always check the following before you initialize the parameter settings.
•
The parameters must not be write prohibited.
•
The servo must be OFF.
Operating Procedure
Use the following procedure to initialize the parameter settings.
Button in
Menu Dialog
Box
Function
When Writing Is Prohibited
Reference
Setup
Origin Search
Cannot be executed.
Absolute Encoder Reset
Cannot be executed.
Motor Current Detection Offset
Adjustment
Cannot be executed.
Cannot be executed.
Multiturn Limit Setting
Cannot be executed.
Vibration Detection Level Initialization Cannot
be
executed.
Set Origin
Cannot be executed.
Polarity Detection
Cannot be executed.
Tuning-less Level Setting
Cannot be executed.
EasyFFT
Cannot be executed.
Parameter
Initialize
*1
Cannot be executed.
Tuning
Autotuning without Reference Input
Cannot be executed.
Autotuning with Reference Input
Cannot be executed.
Custom Tuning
Cannot be executed.
Anti-resonance Control Adjustment
Cannot be executed.
Vibration Suppression
Cannot be executed.
Monitoring
Product Information
Can be executed.
Can be executed.
Can be executed.
Test Run
Jogging
Cannot be executed.
Program Jogging
Cannot be executed.
Alarms
Display Alarm
Can be executed.
*2
Cannot be executed.
Reset Motor Type Alarm
Cannot be executed.
To enable the new settings, turn the power supply to the SERVOPACK OFF and ON again after
you complete the operation.
Important