6.3 FT41 Specification
6.3.3 Parameter Recording Table
6-135
6
Parameter Lists
Pn8A8 to
Pn8BE
0h
Response Data Monitor
during Alarm/Warning (for
maintenance, read only)
–
Pn900
0
Number of Parameter
Banks
After restart
Pn901
0
Number of Parameter Bank
Members
After restart
Pn902 to
Pn910
0000h
Parameter Bank Member
Definition
After restart
Pn920 to
Pn95F
0000h
Parameter Bank Data (Not
saved in nonvolatile mem-
ory.)
Immediately
Pn9B1
0002h
Other Station Monitor 1:
Station Address
After restart
Pn9B2
0003h
Other Station Monitor 1:
Number of Transmission
Bytes
After restart
Pn9B3
1000h
Other Station Monitor 1:
Monitor Information Setting
After restart
Pn9B4
0002h
Other Station Monitor 2:
Station Address
After restart
Pn9B5
3
Other Station Monitor 2:
Number of Transmission
Bytes
After restart
Pn9B6
1000h
Other Station Monitor 2:
Monitor Information Setting
After restart
Pn9B7
0002h
Other Station Monitor 3:
Station Address
After restart
Pn9B8
3
Other Station Monitor 3:
Number of Transmission
Bytes
After restart
Pn9B9
1000h
Other Station Monitor 3:
Monitor Information Setting
After restart
Pn9BA
0002h
Other Station Monitor 4:
Station Address
After restart
Pn9BB
3
Other Station Monitor 4:
Number of Transmission
Bytes
After restart
Pn9BC
1000h
Other Station Monitor 4:
Monitor Information Setting
After restart
Pn9BD
0002h
Other Station Monitor 5:
Station Address
After restart
Pn9BE
3
Other Station Monitor 5:
Number of Transmission
Bytes
After restart
Pn9BF
1000h
Other Station Monitor 5:
Monitor Information Setting
After restart
Pn9C0
0000h
Other Station Monitor Tar-
get Station Selection
Immediately
01
PnA02
–
Encoder Type Selection
(read only)
–
02
PnA04
–
Motor Type Selection
(read only)
–
03
PnA06
–
Semi-closed/Fully-closed
Selection (read only)
–
04
PnA08
–
Rated Motor Speed
(read only)
–
Continued on next page.
Continued from previous page.
Parameter
No.
Default Setting
Name
When
Enabled
Содержание SERVOPACK Sigma 7 Series