5 Installation Procedure
YASKAWA ELECTRIC
TOBP C730600 27B V1000 Option PS-V10 Installation Manual
19
◆
Unplug Drive Cables to Install the 24 V Power Supply Option
(PS-V10S)
If you are installing 24 V Power Supply Option (PS-V10M), proceed to
Cables to Install the 24 V Power Supply Option (PS-V10M) on page 20
.
1. Unplug one end of the existing drive cable from its socket inside the drive as shown in
. Press inward on the cable release tab in the center of the cable connector and
use a flat-blade screwdriver to gently pry up to remove the connector from its socket.
NOTICE:
Do not use excessive force when using a screwdriver to free the drive cable connection. Failure to
comply may damage or break the cable connectors.
Figure 9
Figure 9 Unplugging the Drive Cable Connection (PS-V10S)
2. Next, plug the supplied 24 V Power Supply Option connection cable into the drive cable
socket and click firmly into position as shown in
Note:
Refer to
to verify the correct option part number is used with your drive model.
Connection cables and mounting attachments for 24 V Power Supply Options differ depending
on drive model.
Figure 10
Figure 10 Plugging the Option Connection Cable into the Drive (PS-V10S)
Insert screwdriver into
these two locations to free cable