background image

4

YASKAWA ELECTRIC

 TOBP C730600 27B V1000 Option PS-V10 Installation Manual

1  Preface and Safety

1

Preface and Safety

Yaskawa manufactures products used as components in a wide variety of industrial systems 

and equipment. The selection and application of Yaskawa products remain the responsibility 

of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its 

products are incorporated into the final system design. Under no circumstances should any 

Yaskawa product be incorporated into any product or design as the exclusive or sole safety 

control. Without exception, all controls should be designed to detect faults dynamically and 

fail safely under all circumstances. All systems or equipment designed to incorporate a 

product manufactured by Yaskawa must be supplied to the end user with appropriate 

warnings and instructions as to the safe use and operation of that part. Any warnings 

provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express 

warranty only as to the quality of its products in conforming to standards and specifications 

published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS 

OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses, 

or claims arising from misapplication of its products

Applicable Documentation

The following manuals are available for the 24 V Power Supply Option:

24 V Power Supply Option

Yaskawa AC Drive-V1000 Option 
24 V Power Supply 
Installation Manual
Manual No.: TOBPC73060027
(This book)

Read this manual first.
The installation manual is packaged 
with the 24 V Power Supply Option 
and contains basic installation and 
wiring required for proper use of this 
product.

Yaskawa Drive

Yaskawa AC Drive-V1000 
Quick Start Guide

To obtain instruction manuals for 
Yaskawa products access these sites:
U.S.: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: https://www.e-mechatronics.com
Other areas: contact a Yaskawa 
representative.

For questions, contact the local 
Yaskawa sales office or the nearest 
Yaskawa representative.

Yaskawa AC Drive-V1000 
Technical Manual

STOP

(Hz)

(Hz)
(A)
(V)

:
:
:
:
:
:
:
:
:
:

V1000

周波数指令
正転逆転選択
出力周波数
出力電流
出力電圧
モニタ
ベリファイ
セットアップ
パラメータ設定
オートチューニング

据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後

5

分以内はフロントカバーを

外さないこと。

400V

級インバータの場合は、電源の中性点が接地

されていることを確認すること。(  対応)

けが.感電のおそれがあります。

危 険

Содержание PS-V10M

Страница 1: ...KAWA AC Drive V1000 Option Installation Manual Type PS V10S PS V10M To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user...

Страница 2: ...rior written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high qualit...

Страница 3: ...ption PS V10 Installation Manual 3 Table of Contents 1 PREFACE AND SAFETY 4 2 PRODUCT OVERVIEW 7 3 RECEIVING 8 4 24 V POWER SUPPLY OPTION COMPONENTS 11 5 INSTALLATION PROCEDURE 12 6 VERIFYING OPERATIO...

Страница 4: ...o the end user Yaskawa offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual NO OTHER WARRANTY EXPRESS OR IMPL...

Страница 5: ...ng or servicing this option The option must be installed according to this manual and local codes The following conventions are used to indicate safety messages in this manual Failure to heed these me...

Страница 6: ...bed in this manual or the content and presentation of the manual may be changed without notice to improve the product and or the manual When ordering a new copy of the manual due to damage or loss con...

Страница 7: ...ble to read fault and parameter data in the drive via the LED operator or network communications when the drive switches to the 24 V Power Supply Option as a back up power supply Applicable Models The...

Страница 8: ...ber If you have received the wrong model or this product does not function properly contact your supplier Nameplate Figure 1 Figure 1 Nameplate PS V10S MASS 0 1kg PS V10S EUS610010 DC24V 20 0 41A 10W...

Страница 9: ...tructions on installing the mounting support bracket For questions or ordering information contact your sales representative or Yaskawa Table 3 Types of Mounting Support Brackets not included Descript...

Страница 10: ...l Requirements Screwdriver flat tip A straight edge screwdriver with a blade width of 2 5 mm 3 32 in and a blade thickness of 0 6 mm 1 64 in is required to install the 24 V Power Supply Option Figure...

Страница 11: ...24 V Power Supply Option Power Supply Plug Table 4 Plug Connector Terminals A Option Cover D Mounting Attachment B Power supply display LED E Black socket to drive power board C Plug connector 24 V po...

Страница 12: ...turned off The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc WARNING Electrical Shock Hazard Do not remove option board cover while the power is on Failure to comply cou...

Страница 13: ...power off while the drive is outputting voltage Failure to comply may cause the application to operate incorrectly or damage the drive Do not operate damaged equipment Failure to comply may cause furt...

Страница 14: ...unmounting the drive to simplify installation of the 24 V Power Supply Option Wiring Diagram Figure 5 illustrates the 24 V Power Supply Option and drive interconnections Figure 5 Figure 5 Connection...

Страница 15: ...mounting support bracket listed below is required for compliance with UL and CE Type 1 regulations If these supports are not used the design is considered Open Type Table 5 Applicable Mounting Suppor...

Страница 16: ...own in the figure below Refer to Dimensions on page 30 for screw hole alignment Make sure the supports are properly located relative to the height and positioning the drive Figure 6 Figure 6 Proper In...

Страница 17: ...r Supply is disconnected The drive charge LED will extinguish when the DC bus voltage is below 50Vdc Measure drive DC bus voltage to confirm safe level The 24 V Power Supply Option cover must be separ...

Страница 18: ...e removed to allow access to drive connection sockets prior to mounting the option to the drive 1 Insert a flat blade screwdriver blade into one of the slots on the drives cable access cover and gentl...

Страница 19: ...o remove the connector from its socket NOTICE Do not use excessive force when using a screwdriver to free the drive cable connection Failure to comply may damage or break the cable connectors Figure 9...

Страница 20: ...CE Do not use excessive force when using a screwdriver to free the drive cable connection Failure to comply may damage or break the cable connectors Figure 11 Figure 11 Unplugging the Drive Cable Conn...

Страница 21: ...nd gently press and click the mounting attachment into place as shown in Figure 13 Figure 13 Figure 13 Connecting the Mounting Attachment PS V10S 3 Press firmly on the mounting attachment tabs and mak...

Страница 22: ...page 24 1 Position the drive on its side or its back as shown in Figure 15 Twist the cable with black connector ends 180 degrees 2 Next plug the unit connection cable into the black connector socket C...

Страница 23: ...6 NOTICE Connect the cables exactly as shown in Figure 16 Reversing the cable connections may damage the 24 V Power Supply Option Figure 16 Figure 16 Cable Positioning PS V10S Drive 24 V Power Supply...

Страница 24: ...0M 1 Plug the unit connection cable into the white connector socket CN3 2 labeled TO CONTROLLER on the 24 V Power Supply Option and plug the remaining cable into the black connector socket CN3 1 label...

Страница 25: ...irm both cables are plugged in correctly according to Figure 18 NOTICE Connect the cables exactly as shown in Figure 18 Reversing the cable connections may damage the 24 V Power Supply Option Figure 1...

Страница 26: ...S PS V10M 1 Align the two tabs on the inside edge of the 24 V Power Supply Option with the corresponding slots on the mounting attachment and click the option cover into place Figure 19 Figure 19 Inst...

Страница 27: ...the terminal screws to hold wiring in place Refer to Wire Gauges and Tightening Torque on page 28 NOTICE Properly connect an external 24 V power line to the power supply plug Refer to 24 V Power Suppl...

Страница 28: ...ption cover Refer to Separate the 24 V Power Supply Option Cover and Mounting Attachment on page 17 2 Remove connection cables by pressing on the connector release tabs at the end of each cable to unp...

Страница 29: ...indicates proper operation 3 The LED operator or the LCD operator on the drive should display Uv for about 10 seconds to indicate an undervoltage situation Note If Uv does not flash on the display sc...

Страница 30: ...D3 t1 Single Phase 200 V Class BA0001B 68 128 76 56 34 30 5 118 5 118 6 5 61 7 3 0 8 BA0002B 68 128 76 56 34 30 5 118 5 118 6 5 61 7 3 0 8 BA0003B 68 128 118 56 34 30 5 118 5 118 38 5 61 39 5 1 2 Thr...

Страница 31: ...001B 2 7 5 0 3 0 2 2 1 3 1 2 4 6 0 2 4 6 0 3 2 4 0 3 0 1 1 8 BA0002B 2 7 5 0 3 0 2 2 1 3 1 2 4 6 0 2 4 6 0 3 2 4 0 3 0 1 1 8 BA0003B 2 7 5 0 4 6 2 2 1 3 1 2 4 6 0 2 4 6 1 5 2 4 1 5 0 2 2 6 Three Phase...

Страница 32: ...08B 108 128 129 96 34 30 5 118 5 118 58 61 65 5 5 1 9 2A0010B 108 128 129 96 34 30 5 118 5 118 58 61 65 5 5 1 9 2A0012B 108 128 137 5 96 34 30 5 118 5 118 58 61 65 5 5 1 9 2A0018B 140 128 143 128 34 3...

Страница 33: ...3 1 2 4 7 0 2 4 6 2 3 2 4 2 6 0 2 4 2 2A0010B 4 3 5 0 5 1 3 8 1 3 1 2 4 7 0 2 4 6 2 3 2 4 2 6 0 2 4 2 2A0012B 4 3 5 0 5 4 3 8 1 3 1 2 4 7 0 2 4 6 2 3 2 4 2 6 0 2 4 2 2A0018B 5 5 5 0 5 6 5 0 1 3 1 2 4...

Страница 34: ...54 140 122 34 33 5 234 248 6 13 13 1 5 128 118 12 55 61 67 4 0 2A0056F 180 290 163 160 34 33 5 270 284 6 15 13 1 5 128 118 12 75 61 87 5 7 2A0069F 220 350 187 192 34 33 5 320 336 7 15 22 1 5 128 118 1...

Страница 35: ...0 5 0 5 0 1 5 0 4 6 0 5 2 2 2 4 2 6 8 8 2A0056F 7 1 11 4 6 4 6 3 1 3 1 3 10 6 11 2 0 2 0 6 0 5 0 1 5 0 4 6 0 5 3 0 2 4 3 4 12 6 2A0069F 8 7 13 7 7 4 7 6 1 3 1 3 12 6 13 2 0 3 0 6 0 9 0 1 5 0 4 6 0 5...

Страница 36: ...ower supply to provide power to the 24 V Power Supply Option Using a different type of power supply may result in death or serious injury Item Specifications Option Input Operating Voltage 24 Vdc 20 1...

Страница 37: ...evised Content February 2014 Chapter 3 Revision Nameplate Back cover Revision Address February 2013 Back cover Revision Address November 2010 Front cover Revision Format Back cover Revision Address fo...

Страница 38: ...oad HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC CHINA CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 East Ch...

Отзывы: