background image

Document Revision:  v1.0.5

of

2

10

page

18805 Adams Ct., #110   ~   Morgan Hill, CA 95037, USA   ~  +1-408.924.0808   ~   www.washlinksystems.com   ~   [email protected]

Document Title:  Tech Guide ~ Yaskawa V1000 Basic User Guide 

WASHLINK SYSTEMS

Yaskawa V1000 Basic User Guide

This document provides basic information for navigating and adjusting your Washlink Systems 
supplied Yaskawa V1000 Variable Frequency Drive.

When emailing or  calling for assistance, you must have the following information available:

Location Name:

______________________________

Contact Person:

______________________________

Contact Phone:

______________________________

VFD Model:

______________________________

Equipment connected: ______________________________

Distributor Name:

______________________________

COPYRIGHT

2013 Washlink Systems.  All rights reserved.

THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF WASHLINK SYSTEMS AND IS PREPARED 
ONLY FOR USE BY THE COMPANY PURCHASING THE EQUIPMENT.  EDITING, COPYING, 
DISTRIBUTING, AND/OR SELLING THIS DOCUMENT IS STRICTLY PROHIBITED WITHOUT PRIOR 
WRITTEN CONSENT FROM WASHLINK SYSTEMS.  WASHLINK SYSTEMS RESERVES THE RIGHT 
TO EDIT THIS DOCUMENT IN ANY MANNER DEEMED NECESSARY, AT ANY TIME, AND WITHOUT 
PRIOR NOTICE.

Содержание PROFINET V1000

Страница 1: ...Document Revision v1 0 5 of 1 10 page 18805 Adams Ct 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Tech Guide Yaskawa V1000 Basic User Guide ...

Страница 2: ..._____________________________ Contact Person ______________________________ Contact Phone ______________________________ VFD Model ______________________________ Equipment connected ______________________________ Distributor Name ______________________________ COPYRIGHT 2013 Washlink Systems All rights reserved THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF WASHLINK SYSTEMS AND IS PREPARED ONLY FOR US...

Страница 3: ...t Current Amps Output Voltage Monitor Display typically not used Verify Menu typically not used Set Up Mode typically not used Parameter Setting mode Auto Tuning Hz drive set to run Forward Selection Reverse Selection typically not used Standard Operator Panel Display To Change Display Data View The standard screen after a power cycle is the actual output in Hz xx xx To change data being displayed...

Страница 4: ...ameter A1 02 with the A flashing ENTER Press the or or to get to the parameter you want to adjust then press ENTER RESET You will now see the current setting for the selected parameter left digit will flashing Press the or or to change the parameter then press ENTER RESET With the VFD powered on and the motor not running You will now see the next parameter with the left digit flashing 1 2 3 4 5 6 ...

Страница 5: ...econds If used typically between 1 0 3 0 note if more then one motor on same sensor times must be different to prevent drive speed bouncing C1 01 Acceleration time 1 in seconds Typically between 3 0 15 0 C1 02 Deceleration time 1 in seconds Typically between 3 0 25 0 d1 01 Frequency Reference 1 speed in Hz Typically between 35 0 60 0 d1 02 Frequency Reference 2 speed in Hz Typically between 35 0 6...

Страница 6: ...termined internally U1 13 Terminal A1 Input Level Displays analog input A1 level 100 when input is 10 V U1 14 Terminal A2 Input Level Displays analog input A1 level 100 when input is 10 V U3 01 Most Recent Fault Displays the most recent fault U3 02 2nd Most Recent Fault Displays the second most recent fault U3 03 3rd Most Recent Fault Displays the third most recent fault U3 04 4th Most Recent Faul...

Страница 7: ...s damaged Check the insulation resistance Replace the motor One of the motor cables has shorted out or there is a grounding problem Check the motor cables Check the resistance between the motor cables and the ground terminal Replace damaged cables The load is too heavy Reduce the load to avoid sudden changes in the current level or switch to a larger drive The acceleration or deceleration times ar...

Страница 8: ...t power Check for wiring errors in the main circuit drive input power There is loose wiring in the drive input power terminals Ensure the terminals are tightened properly There is excessive fluctuation in the drive input voltage Check the voltage from the drive input power There is poor balance between voltage phases Stabilize drive input power or disable phase loss detection Over Voltage Decelera...

Страница 9: ...t 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Document Title Tech Guide Yaskawa V1000 Basic User Guide Revision history v1 0 1 Initial release v1 0 3 Various typo s v1 0 5 Fixed red display box images ...

Страница 10: ...ent Revision v1 0 5 of 10 10 page 18805 Adams Ct 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Document Title Tech Guide Yaskawa V1000 Basic User Guide Notes ...