A.2 Parameter Table
340
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
No.
Name
Description
Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
LV
P
M
L1: Motor Protection Functions
Use L1 parameters to configure motor protective functions.
L1-01
Motor Overload
Protection Selection
Sets the motor thermal overload protection
(OL1) based on the cooling capacity of the
motor.
0: Disabled
1: Standard Fan Cooled (speed range < 10:1)
2: Standard Blower Cooled (speed range
≥
10:1)
3: Vector Motor (speed range 100:1)
4: PM motor with variable torque
NOTICE:
When multiple motors are used the
drive may not be able to provide protection,
even if it is enabled in L1-01. Set L1-01 to “0”
and ensure each motor has a thermal relay
installed.
0 to 4
1
S S S
480
L1-02
Motor Overload
Protection Time
Sets the motor thermal overload protection
(OL1) time.
A larger L1-02 time will increase the time for
an OL1 fault to occur.
This parameter does not typically require
adjustment. Should be set in accordance with
the overload tolerance of the motor.
0.1 to
5.0
1.0
min
A A A
481
L1-03
Motor Overheat Alarm
Operation Selection
(PTC input)
Sets operation when the motor temperature
analog input (H3-02/10 = E) exceeds the OH3
alarm level.
0: Ramp to Stop
1: Coast to Stop
2: Fast-stop using C1-09
3: Alarm Only (“oH3” will flash)
0 to 3
3
A A A
482
L1-04
Motor Overheat Fault
Operation Selection
(PTC input)
Sets stopping method when the motor
temperature analog input (H3-02/10 = E)
exceeds the OH4 fault level.
0: Ramp to Stop
1: Coast to Stop
2: Fast-stop
0 to 2
1
A A A
483
L1-05
Motor Temperature
Input Filter Time (PTC
input)
This parameter adjusts the filter on the motor
temperature analog input (H3-02 or H3-10 = E).
Increase to add stability, decrease to improve
response.
0.00 to
10.00
0.20 s A A A
484
Содержание OYMC V1000
Страница 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Страница 294: ...2 12 Self Diagnostics 294 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Страница 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...