5.5 Sigma-5 I/O
5.4.2 Outputs
18
5.5 Sigma-5 I/O
The Sigma-5 includes seven digital inputs and three digital outputs
that can be monitored & controlled by the MP2600iec.
SO1+ / BK+
SO1- / BK-
/SO2+
/SO2-
/SO3+
ALM+
ALM-
1
2
23
24
3
4
+24V
3.3k
Ω
/SI1
/SI2
/SI3
/SI4
/SI5
6
8
10
9
11
12
/SI6
/SI0
BAT+
BAT-
13
14
15
7
/SO3-
PBO
PCO
/PBO
PAO
/PAO
/PCO
19
25
26
17
18
20
21
22
16 SG
*
1
CN1
Command option
module input 3*
4
Command option
module input 4*
4
Command option
module input 5*
4
Command option
module input 6*
4
Encoder output
pulses phase A
Encoder output
pulses phase B
Encoder output
pulses phase C
General-purpose outputs
General-purpose input 0
Backup battery*
2
(2.8 to 4.5 V)
Reverse run prohibited
(Prohibited when OFF)
Forward run prohibited
(Prohibited when OFF)
Servo alarm output
(OFF for an alarm)
Photocoupler output
Max. operating voltage: 30 VDC
Max. operating current: 50 mA DC
Brake output
(Brake released when ON)
Applicable line
receiver
SN75ALS175
manufactured by
Texas Instruments
or an MC3486
equivalent
Signal ground
SGDV SERVOPACK
Control power supply
for sequence signal*
3
Содержание MP2600iec
Страница 1: ...MP2600iec Hardware Manual...
Страница 2: ......
Страница 8: ...1 3 Dimensions 1 3 1 MP2600iec Controller 6...
Страница 24: ...6 1 Switch Settings 22...
Страница 26: ...24...
Страница 33: ...10 1 CBK U MP2B xx 31 10 Cable Diagrams 10 1 CBK U MP2B xx Terminal Block Controller...
Страница 35: ...10 3 SBK U VBA xx 33 10 3 SBK U VBA xx Terminal Block Servo Amplifier...
Страница 38: ...36...
Страница 40: ...38...
Страница 41: ......