![YASKAWA MOTOMAN MYS450L Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/yaskawa/motoman-mys450l/motoman-mys450l_operating-and-maintenance-instructions-manual_3252846039.webp)
39
7.2.1
Electric cable
Contacts marked with identical numbers on the connections at both cable ends are connected
to each other.
7.2.2
pneumatic tubes
Fittings for ø 6 mm and ø 4 mm (outer diameter) for pneumatic hoses are provided at both
hose ends.
Table 3
Internal wiring
Rated Voltage
Current
Capacity
Leads
Nominal cross
section
outside diameter
Notice
AC/DC30 V
1 A
15
0.211 mm
2
ø8.3±0.3 mm
shielded
Table 4
Connector types
Maker
Stdandard
15 pin
Applicable plug:
JAE
DA-15PF-N (Solder Type)
Clamping hood
JAE
DA-C8-J10-F2-1 (connection setscrew: #4-40 NC)
9 pin
Applicable plug:
JAE
DE9PF-N (Solder Type)
Clamping hood
JAE
DE-C8-J9-F2-1R (connection setscrew: #4-40 NC)
Table 5
Internal pneumatic tubes
Max. permissible pneumatic pressure
pneumatic tubes
Outside diameter × Inside diameter
0.59 Mpa
2
ø6 mm x ø4 mm
1
ø4 mm x ø2,5 mm
Содержание MOTOMAN MYS450L
Страница 24: ...24 E1101000117GB01 MYS450L 5 2 Part Names and Working Axes 1 2 3 5 4 6 7 15 14 13 12 11 10 9 8 15 Back View...
Страница 26: ...26 E1101000117GB01 MYS450L 5 3 Dimensions 4 5 12 1 200 6 7 8 9 10 3 11 Dimensions mm...
Страница 40: ...40 E1101000117GB01 MYS450L 8 Electrical Equipment Specification 8 1 Signal cable BASE ARM2...
Страница 41: ...MYS450L E1101000117GB01 41 8 2 Power cable BASE ARM2...
Страница 60: ...60 E1101000117GB01 MYS450L...
Страница 61: ...MYS450L E1101000117GB01 61...