Wiring
5
-
22
5
Wiring
DANGER!
Danger to life due to electric shock, risk of fire due to short circuit.
Wiring must be performed by authorized or certified personnel.
Follow the instructions given below before wiring.
Make sure that the earthing resistance does not exceed 0.1
Ω
.
Turn OFF the main power supply.
Put up the warning sign prescribed, e.g.
"Do not turn the power on!"
.
Install a switch-on guard as prescribed.
5.1
Grounding
Follow the applicable electrical installation standards and wiring regulations for earthing.
The cable cross-section must be 6 mm² or more.
For information on connecting the earthing cable directly, see Fig. 5-1: "Earthing
connection".
NOTICE
Note on the earthing connection
Never use the earthing cable together with an earthing cable of, for example:
A different electrical consumer
A different motor-driven consumer
Welding devices, etc.
If the earthing cable is laid in a metal duct, metal conduit or some other metal system, this
must be earthed in accordance with the applicable electrical installation standards.
Fig. 5-1: Earthing connection
M8 screw for earthing is supplied with the robot (at least 6 mm² protective earth con-
ductor).
1
1
Содержание MH5S II
Страница 1: ...ROBOTICS MH5S II YR MH0005S J12 Operating and Maintenance Manual...
Страница 19: ...Installation 4 19 Fig 4 2 Base plate 3 160 30 4x 80 350 350 290 290 160 18 50 4x 20 24 4...
Страница 32: ...Technical data 6 32 Robot speed degrees second deg s Definitions Description...
Страница 47: ...Maintenance and inspection 9 47 Fig 9 2 Inspection intervals 5 5 5 7 1 1 1 1 1 6 1 3...
Страница 73: ...Parts lists 11 73 Tab 11 1 S axis drive 1049 HW0414484 1 Gasket 1 No DWG no Designation Piece...
Страница 82: ...YASKAWA Headquarter...