1.2 General Description
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
23
Re
ce
iv
ing
1
1.2
General Description
u
L1000V Model Overview
Note:
The drive automatically decreases the rated output current when setting higher carrier frequency.
u
Control Mode Selection
gives an overview of the L1000V motor control methods (control modes) and their various features.
Table 1.1 Control Modes and their Features
Motor Power
kW
<1> These values assume the carrier frequency is not set higher than 8 kHz.
3-Phase 200 V Class
3-Phase 400 V Class
Model CIMR-LC
Rated Output Current (A)
Model CIMR-LC
Rated Output Current (A)
4.0
2V0018
17.5
4V0009
9.2
5.5
2V0025
25
4V0015
14.8
7.5
2V0033
33
4V0018
18
11
2V0047
47
4V0024
24
15
2V0060
60
4V0031
31
Motor Type
Induction Motors
Comments
Control Mode
V/f
V/f with PG
OLV
OLV with PG
–
Parameter Setting
A1-02 = 0
H6-01 = F
A1-02 = 0
H6-01 = 3
A1-02 = 2
H6-01 = F
A1-02 = 2
H6-01 = 3
Default Setting is V/f Control.
Basic Description
V/f control
V/f control with
simple PG
feedback
Open Loop Vector
control
Open Loop Vector
control with simple
PG feedback
PG feedback is only one channel input to the drive pulse
train input terminal. Cannot determine motor direction.
Type of Applications
Motor Type
IM
IM
IM
IM
–
PG Feedback
N/A
YES, 1CH
N/A
YES, 1CH
–
Control
Characteristics
Speed Control Range
1:40
1:40
1:100
1:100
May fluctuate with characteristics and motor temperature.
Speed Accuracy
±
2.0%
±
0.03%
±
0.2%
±
0.03%
Speed deviation when operating at constant speed. May
fluctuate with characteristics and motor temperature.
Speed Response
3 Hz
3 Hz
5 Hz
5 Hz
Max. frequency of a speed reference signal that the drive
can follow. May fluctuate with characteristics and motor
temperature.
Starting Torque
150% at 3 Hz
150% at 3 Hz
200% at 0.5 Hz
200% at 0.5 Hz
May fluctuate with characteristics and motor temperature.
Performance may differ by capacity.
Application-Specific
Auto-Tuning
Line to line
resistance
Line to Line
resistance
• Rotational
• Stationary
• Line to line
resistance
• Rotational
• Stationary
• Line to line
resistance
Automatically adjusts parameter settings that concern
electrical characteristics of the motor.
Torque Limit
N/A
N/A
YES
YES
Sets the maximum torque for the motor to protect the load
and connected machinery.
DC Injection at Start
and Stop
YES
YES
YES
YES
Builds up motor torque when stopped in order to prevent
movement of the elevator when the brake is released at
start and applied at stop.
Torque compensation
N/A
N/A
YES
YES
Torque boost at start.
Slip compensation
YES
YES
YES
YES
Adjusts the leveling speed reference in order to improve
the stopping accuracy.
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...