30
YASKAWA
TOMPYEULA7002A LA700 Series Installation and Operation Instruction
b1-01 Settings
Reference Source
Speed Reference Input
0 (default)
Keypad
The drive uses the keypad to enter the speed reference.
1
Analog input
The drive uses MFAI terminals A1 or A2 to input an analog speed reference with a voltage or current
input signal.
2
Serial communication
The drive uses the serial communication port RS-485 to enter the speed reference.
3
Option board
The drive uses a communications option card or input option card connected to the drive to enter the
speed reference.
*1
When
b1-01 = 1 [Analog Input]
, the drive will automatically set
d1-18 = 0 [Speed Reference Selection Mode = Multi-speed Mode1
(d1-01 to 08)]
.
*2
When
d1-18 = 1 or 2 [High speed has priority or Leveling speed has priority]
, the speed reference entered from MFDI terminals will
have priority over other speed references.
Up/Down Command Selection
Parameter
b1-02 [Up/Down Command Selection 1]
sets the Up/Down command source.
b1-02 Settings
Up/Down Command Source
Up/Down Command Input
0
Keypad
The drive uses the keypad to enter the Up/Down command.
1 (default)
Digital input
The drive uses the control circuit terminals to enter the Up/Down command. Select the input method
for the Up/Down command with an
H1-xx
parameter.
2
Serial communication
The drive uses the serial communication port RS-485 to enter the speed reference.
3
Option board
The drive uses a communications option card or input option card connected to the drive to enter the
speed reference.
Travel Start
To start the elevator in the Up or Down direction, make sure that you do these items:
•
Select a speed reference greater than zero.
•
Close the Safe Disable signals at terminals H1 and H2.
•
Set an Up or Down Signal at the source specified in
b1-02 [Up/Down Command Selection 1]
.
Travel Stop
The drive stops when:
•
You clear the Up or Down command.
•
You set
d1-18 = 1 or 2 [Speed Reference Selection Mode = High speed has priority or Leveling speed has
priority]
and clear the Up/Down or
Leveling Speed
signal (
H1-xx = 53
).
•
You set
d1-18 = 3 [Multi-speed Mode2 (d1-02 to 08)]
and clear all speed inputs.
•
The drive detects a fault. There are different stopping methods for different faults and parameter settings.
•
The Safe Disable inputs are opened or a Baseblock signal is input. When one of these occurs, the brake is
applied immediately and the drive output shuts off.
■
Brake Sequence
shows the brake sequence and parameters to use for adjustment.
Figure 1.10 Brake Sequence
Содержание LA700 Series
Страница 316: ...9 316 YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction 9 3 9 4 A B C 5 D 9 4...
Страница 322: ...9 322 YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction 9 7 1 1 2 B1 B2...
Страница 324: ...9 324 YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction 9 9 1 MEMOBUS Modbus H5 11 1...