12.6 H: Terminal Function Selection
310
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
■
56: Motor Contractor Feedback
Setting Value
Function
Description
56
Motor Contractor Feedback
Used for motor contactor supervision and fault detection.
■
79: Brake Feedback
Setting Value
Function
Description
79
Brake Feedback
Used for brake supervision and detection of incorrect operation.
◆
H2: Digital Outputs
H2 parameters
set the MFDO terminal functions.
■
H2-01 to H2-03 Terminal MA/MB-MC, P1-C1, P2-C2 Function Selection
The drive has three MFDO terminals.
shows the default function settings for the terminals.
Table 12.7 MFDO Terminals Default Function Settings
No.
Name
Default
Function
H2-01
Term MA/MB-MC Function Selection
(Contact)
E
Fault
H2-02
Term P1-C1 Function Selection
6
Drive Ready
H2-03
Term P2-C2 Function Selection
50
Brake Control
Refer to
to set
H2-xx [MFDO Function Select]
.
Table 12.8 MFDO Setting Values
Setting Value
Function
Reference
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
B
Torque Detection 1 (N.O.)
E
Fault
F
Not Used
10
Alarm
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
Setting Value
Function
Reference
18
Torque Detection 2 (N.O.)
1A
During Reverse
1B
During Baseblock (N.C.)
1E
Executing Auto-Restart
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-Alarm (oH)
21
Safety Monitor Output Status
2F
Maintenance Notification
30
During Torque Limit
37
During Frequency Output
47
PF Detection
50
Brake Control
51
Output Contactor Control
54
Light Load Direction
58
Safe Disable Status
100 to 158
Inverse output of 0 to 58
Sets an inverse output of the function for
the MFDO. Put a 1 at the front of the
function setting to set inverse output. For
example, set
H2-xx = 10E
for the inverse
output of
E [Fault]
.
*1
Inverse output is not available.
V/f
OLV
V/f
OLV
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...