7.8 Backup Function Operating Mode Display and Errors
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
195
7.8
Backup Function Operating Mode Display and Errors
◆
Operating Mode Display
When you use the LCD keypad to do the backup function, the keypad shows the running operation on the LCD
display. These indicators do not show that an error has occurred.
Keypad Display
Name
Display
Status
Drive and Keypad mismatch.
Should the parameters be
restored?
Detection of inconsistency between the
drive and keypad
Normally displayed
The drive detected the connection of a
keypad from a different drive. Select [Yes]
to copy parameters backed up in the
keypad to the connected drive.
Restore Restore from keypad
Restoring parameters
Flashing
The parameters stored in the keypad have
been restored to the drive.
End
Backup/restore/verify operation ended
normally
Normally displayed
The parameter backup, restore, or verify
operation ended normally.
Backup Backup from Drive
Backing up parameters
Flashing
The parameters stored in the drive are
being backed up to the keypad.
Verify Keypad & Drive
Verifying parameters
Flashing
The parameter settings stored in the
keypad and the parameter settings in the
drive match or are being compared.
◆
Backup Function Runtime Errors
When an error occurs, the keypad shows a code to identify the error.
The table in this section show the error codes. If there are errors, refer to these tables:
Note:
Push any key on the keypad to clear an error.
Code
Name
Causes
Possible Solutions
CPEr
Control Mode Mismatch
The keypad setting and drive setting for
A1-02
[Control Method Selection]
do not agree.
1.
Set
A1-02
on the drive to the same value that is on the
keypad.
2.
Restore the parameters.
Code
Name
Causes
Possible Solutions
CPyE
Error Writing Data
Parameter restore did not end correctly.
Restore the parameters.
Code
Name
Causes
Possible Solutions
CSEr
Control Mode Mismatch
The keypad is broken.
Replace the keypad.
Code
Name
Causes
Possible Solutions
dFPS
Drive Model Mismatch
You tried to restore parameters to a different drive
model than the one that you backed up.
1.
Examine the drive model that you used to back up the
parameters.
2.
Restore the parameters.
Code
Name
Causes
Possible Solutions
iFEr
Keypad Communication Error
There was a communications error between the
keypad and the drive.
Examine the connector or cable connection.
Code
Name
Causes
Possible Solutions
ndAT
Error Received Data
The parameter settings for model and specifications
(power supply voltage and capacity) are different
between the keypad and the drive.
1.
Make sure that drive model and the value set in
o2-04 [Drive
Model (KVA) Selection]
agree.
2.
Restore the parameters.
The parameters are not stored in the keypad.
1.
Connect a keypad that has the correct parameters.
2.
Restore the parameters.
Code
Name
Causes
Possible Solutions
rdEr
Error Reading Data
You tried to back up the data when
o3-02 = 0 [Copy
Allowed Selection = Disabled]
.
Set
o3-02 = 1 [Enabled]
and back up again.
Code
Name
Causes
Possible Solutions
vAEr
Voltage Class, Capacity Mismatch
The power supply specifications or drive capacity
parameter settings are different between the keypad
and the drive.
1.
Make sure that drive model and the value set in
o2-04 [Drive
Model (KVA) Selection]
agree.
2.
Restore the parameters.
Code
Name
Causes
Possible Solutions
vFyE
Parameters do not Match
The parameters that are backed up in the keypad
and the parameters in the drive are not the same.
1.
Restore or backup the parameter again.
2.
Verify the parameters.
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...