4 LED Operator Option Components
14
YASKAWA ELECTRIC
TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
◆
LED Operator LED Status Indicators
Table 6 LED Status and Meaning
Figure 3
Figure 3 RUN LED Status
LED
Illuminated
Flashing
<1> For the difference between “Flashing” and “Flashing Quickly” of the RUN LED, refer to
, RUN LED
Status.
Flashing
Quickly
Off
LO/RE
LED
When the run
command is selected
from the LED
operator (LOCAL).
–
–
Run command is
selected from a
device other than the
LED operator
(REMOTE).
RUN LED
During run.
• During
deceleration to
stop.
• When a run
command is input
and the frequency
reference is 0 Hz.
• During
deceleration at a
fast-stop.
• During stop by
External Fault
digital input.
During stop.
RE
LO
RUN
Flashing
quickly
Flashing
O
N
O
N
O
N
O
N
O
N
O
N
1 s