YASKAWA JVOP-181 Скачать руководство пользователя страница 17

6  Using the Copy Function

YASKAWA ELECTRIC

 

TOBPC73060025B USB Copy Unit Technical Manual

 

17

ndAT

• Model, voltage class, capacity, and/or 

control mode differ

<1>

• No data is saved to the copy unit

<4>

rdEr

Error reading data

<5>

rEAd

Reading parameter settings (flashing)

vAEr

Voltage class and/or drive capacity does not 
match

<1>

vFyE

Parameter settings in the drive and those 
saved to the copy unit are not the same

vrFy

Comparing parameter settings (flashing)

 

<1> Parameters can only be copied to a drive when the power 

supply specifications, capacity, control mode, and software 

version match.

<2> Press and hold the Copy button for one second. The copy unit 

will copy parameter settings previously saved to the copy unit 

to the drive.

<3> Replace the copy unit.

<4> Connect the copy unit to a drive with the proper parameter 

settings and press and hold the Read button for one second. 

The copy unit will then save the settings from the drive.

<5> Press and hold the Read button for one second. The copy unit 

will save the settings from the drive.

Display

Description

Содержание JVOP-181

Страница 1: ...e the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives this manual Technical Manual USB Copy Unit YASKAWA AC Drive Option C o p...

Страница 2: ...This Page Intentionally Blank...

Страница 3: ...al Manual 3 Contents 1 PREFACE AND SAFETY 5 2 RECEIVING 7 3 PRODUCT OVERVIEW 8 4 COMPONENTS AND FUNCTIONS 9 5 CONNECTION THE DRIVE TO A PC 12 6 USING THE COPY FUNCTION 14 7 SPECIFICATIONS 18 8 YASKAWA...

Страница 4: ...written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quality pro...

Страница 5: ...fety messages in this manual Failure to heed these messages could result in serious or possibly even fatal injury or damage to the products or to related equipment and systems NOTICE will also be indi...

Страница 6: ...A ELECTRIC TOBPC73060025B USB Copy Unit Technical Manual Safety Messages WARNING Electrical Shock Hazard Do not remove covers or touch circuit boards while the power is on Failure to comply could resu...

Страница 7: ...g Please perform the following tasks after receiving the copy unit 1 Inspect the copy unit for damage If the copy unit appears damaged upon receipt contact the shipper immediately 2 Verify receipt of...

Страница 8: ...C software includes DriveWizardPlus and DriveWorksEZ DriveWizardPlus is used for editing parameters operating the drive and monitoring drive performance when the drive is connected to a PC DriveWorksE...

Страница 9: ...unit to a drive using the provided RJ 45 cable USB port connects the copy unit to a PC using the provided USB cable Note When connecting the copy unit to a PC or drive use only the cables provided Ya...

Страница 10: ...nd to activate the function Saves parameter settings from the drive Verify 1 Compares parameters on the drive with the settings saved to the copy unit Copy 1 Copies parameters settings that have been...

Страница 11: ...e unit 1 OFF OFF Cable is not properly connected 2 OFF ON Indicates an error in the copy unit 3 1 After properly setting all drive parameters connect the copy unit and press and hold the Read button f...

Страница 12: ...and Instructions Note For instructions on connecting a PC to the drive refer to the drive technical manual Connect A1000 to the USB port on any PC using a USB cable Drive Connection Port Port Locatio...

Страница 13: ...onics com Other areas contact a Yaskawa representative 2 All communication ports in this copy unit are used to connect to a PC or drive using the cables provided 3 Use DriveWizardPlus or DriveWorksEZ...

Страница 14: ...n of drive or equipment Parameters can only be saved to a drive when the voltage class capacity control mode and software version match Connecting the Copy Unit and Instructions Using the copy unit wi...

Страница 15: ...utton for one second to save parameters from the drive to the copy unit While saving settings from the drive to the copy unit will flash on the display screen Verify Press and hold the Verify button f...

Страница 16: ...will flash on the display screen Drive LED Display and Meaning Use the table below to understand the drive LED when the copy unit is connected Display Description CoPy Writing parameter settings flash...

Страница 17: ...parameter settings flashing 1 Parameters can only be copied to a drive when the power supply specifications capacity control mode and software version match 2 Press and hold the Copy button for one s...

Страница 18: ...ions 7 Specifications Item Specification Port RJ 45 USB 2 0 Power supply Powered from a PC or drive Operating system Windows 2000 XP Memory Stores parameters settings for a single drive Operating temp...

Страница 19: ...ton Woods Cumbernauld G68 9LF United Kingdom Phone 44 1236 735000 Fax 44 1236 458182 YASKAWA ELECTRIC KOREA CORPORATION 7F Doore Bldg 24 Yeoido dong Youngdungpo Ku Seoul 150 877 Korea Phone 82 2 784 7...

Страница 20: ...re given on the bottom of the back cover Date of Publication Rev No Section Revised Content January 2008 First edition August 2008 All chapters Revision The title of the Manual Addition Application to...

Страница 21: ...eof the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations Therefore be sure to follow all procedures and submit all relevant documenta...

Отзывы: