3 Conditions of Acceptability
YASKAWA ELECTRIC
TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual
11
◆
Installation Spacing
Figure 5
illustrates correct installation spacing for proper airflow, and wiring. The drive
should be installed so that the heatsink plate rests flat against the metal back panel to ensure
proper cooling.
Table 4 Correct Installation Spacing
Table 5 Correct Installation Spacing
NOTICE:
Do not install J1000 Finless drives using the Side-by-Side method available in standard J1000
drive models. Improper drive cooling may result in damage to the drive. Install J1000 Finless drives with a
minimum side-by-side clearance of 30 mm (1.18 in).
Side Clearance
Top/Bottom Clearance
Voltage Class
Drive Model
CIMR-J
Side Clearance (a)
mm / (in)
Single-Phase 200 V Class
BA0001 to BA0010
30 / (1.18)
Three-Phase 200 V Class
2A0001 to 2A0020
Three-Phase 400 V Class
4A0001 to 4A0011
a
a
Metal
panel
100 mm
minimum
100 mm
minimum