460
YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
2.13
T: Auto-Tuning
T parameters
set input data for:
•
Induction Motor Auto-Tuning
•
PM Motor Auto-Tuning
◆
T0: Tuning Mode Selection
■
T0-00: Tuning Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
T0-00
(1197)
Tuning Mode Selection
Sets the type of Auto-Tuning.
0
(0)
0 : Motor Parameter Tuning
Note:
The available tuning modes are different for different control methods.
◆
T1: Induction Motor Auto-Tuning
T1 parameters
set the Auto-Tuning input data for induction motor tuning.
Note:
•
The base frequency of drive-dedicated motors and special vector-control motors can be lower than the base frequency of general-purpose
motors, which is 50 Hz or 60 Hz. In these conditions, the drive uses the lower frequency as the value for
E1-06 [Base Frequency]
and
E1-
04 [Maximum Output Frequency]
after Auto-Tuning completes. If the maximum output frequency is too low and causes problems, change
the setting of
E1-04
after Auto-Tuning completes.
•
The drive automatically sets these induction motor parameters:
–
E1-xx [V/f Pattern for Motor 1]
–
E2-xx [Motor Parameters]
–
E3-xx [V/f Pattern for Motor 2]
–
E4-xx [Motor 2 Parameters]
■
T1-00: Motor 1/Motor 2 Selection
No.
(Hex.)
Name
Description
Default
(Range)
T1-00
(0700)
Motor 1/Motor 2 Selection
Sets which motor to tune when motor 1/2 switching is enabled.
1
(1, 2)
Note:
This parameter is available when
H1-xx = 16 [Motor 2 Selection]
. The keypad will not show this parameter when
H1-xx ≠ 16
.
1 : Motor 1 (sets E1-xx, E2-xx)
Auto-Tuning automatically sets parameters
E1-xx
and
E2-xx
for motor 1.
2 : Motor 2 (sets E3-xx, E4-xx)
Auto-Tuning automatically sets parameters
E3-xx
and
E4-xx
for motor 2. Make sure that you connect motor 2 to the
drive for Auto-Tuning.
■
T1-01: Auto-Tuning Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
T1-01
(0701)
Auto-Tuning Mode Selection
Sets the type of Auto-Tuning.
0
(0, 2)
0 : Rotational Auto-Tuning
2 : Stationary Line-Line Resistance
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 16: ...i 3 Warranty Information 16 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 158: ...1 22 Defaults by o2 04 Drive Model kVA Selection 158 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 506: ...2 14 Y Application Features 506 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...