YASKAWA
TOEPC71061737D GA800 DRIVE INSTALLATION & PRIMARY OPERATION
107
The keypad shows
oH3
and the drive continues operation. The output terminal set for
Alarm [H2-01 to H2-03 = 10]
activates.
■
L1-04: Motor Thermistor oH Fault Select
No.
(Hex.)
Name
Description
Default
(Range)
L1-04
(0483)
Motor Thermistor oH Fault
Select
Sets the drive operation when the PTC input signal to the drive is at the
oH4 [Motor Overheat Fault
(PTC Input)]
detection level.
1
(0 - 2)
0 : Ramp to Stop
The drive ramps the motor to stop in the deceleration time. Fault relay output terminal MA-MC turns ON, and MB-
MC turns OFF.
1 : Coast to Stop
The output turns OFF and the motor coasts to stop. Fault relay output terminal MA-MC turns ON, and MB-MC turns
OFF.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. Fault relay output terminal MA-MC
turns ON, and MB-MC turns OFF.
13
European Standards
Figure 13.1 CE Mark
The CE Mark identifies that the product meets environmental and safety standards in the European Union. Products
manufactured, sold, or imported in the European Union must display the CE Mark.
European Union standards include standards for electrical appliances (Low Voltage Directive), standards for electrical
noise (EMC Directive), and standards for machinery (Machinery Directive).
This product displays the CE Mark in accordance with the Low Voltage Directive, the EMC Directive, and the
Machinery Directive.
Table 13.1 Harmonized Standards
European Directive
Harmonized Standards
CE Low Voltage Directive Compliance
2014/35/EU
EN 61800-5-1
Electromagnetic Compatibility Regulations
2014/30/EU
EN 61800-3
Machinery Directive
2006/42/EC
•
EN ISO 13849-1:2015 (PL e (Cat.III))
•
IEC 62061 (SILCL3)
•
EN 62061 (SILCL3)
•
IEC/EN 61800-5-2 (SIL3)
Restriction of the use of certain hazardous substances (RoHS)
2011/65/EU
EN IEC 63000
*1
Refer to
EU Declaration of Conformity on page 108
for the year of the Harmonized Standards.
The customer must display the CE Mark on the final device containing this product. Customers must verify that the
final device complies with EU standards.
Table 13.2 Other Applicable Standards
European Directive
Applicable Standards
EU ErP Directive
2009/125/EC
The drive meets the requirements for IE2 efficiency according to the European regulation
2019/1781.
The losses and the efficiency were measured in accordance with the requirements of IEC
61800-9-2.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV