10.9 Knock-Out Hole Dimensions (IP20/UL Type 1)
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
473
10.9
Knock-Out Hole Dimensions (IP20/UL Type 1)
◆
Models and Dimensions of Knock-Out Hole
Model
Reference
2004 to 2042
4002 to 4023
2056
4031, 4038
2070, 2082
4044, 4060
2110
4075
2138
4089, 4103
2169
4140, 4168
2211
2257, 2313
4208 - 4302
2360
■
2004 to 2042, 4002 to 4023
Figure 10.20 Knock-Out Dimensions Diagram 1 (Model: 2004 to 2042, 4002 to 4023)
Model
Dimensions mm (in)
D
D1
D2
D3
W
φ
d4
2004 to 2012
4002 to 4005
39
(1.54)
85
(3.35)
57.5
(2.26)
30
(1.18)
38.2
(1.50)
35
(1.38)
2018 to 2042
4007 to 4023
74
(2.91)
85
(3.35)
57.5
(2.26)
30
(1.18)
38.2
(1.50)
35
(1.38)
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...