6.3 MEMOBUS/Modbus Communications
304
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
Minor Fault/
Alarm Code
(Hex.)
Name
000B
EF5 [External Fault (Terminal S5)]
000C
EF6 [External Fault (Terminal S6)]
000D
EF7 [External Fault (Terminal S7)]
000E
EF8 [External Fault (Terminal S8)]
0010
oS [Overspeed]
0011
dEv [Speed Deviation]
0012
PGo [Encoder (PG) Feedback Loss]
0014
CE [Modbus Communication Error]
0015
bUS [Option Communication Error]
0016
CALL [Serial Comm Transmission Error]
0017
oL1 [Motor Overload]
0018
oL2 [Drive Overloaded]
001A
EF0 [Option Card External Fault]
001B
rUn [Motor Switch during Run]
001D
CALL [Serial Comm Transmission Error]
001E
UL3 [Undertorque Detection 1]
001F
UL4 [Undertorque Detection 2]
0020
SE [Modbus Test Mode Error]
0021
L24v [Loss of External Power 24 Supply]
0022
oH3 [Motor Overheat (PTC Input)]
0027
FbL [PID Feedback Loss]
0028
FbH [Excessive PID Feedback]
002A
dnE [Drive Disabled]
002B
PGoH [Encoder (PG) Hardware Fault]
Minor Fault/
Alarm Code
(Hex.)
Name
0031
E5 [MECHATROLINK Watchdog Timer Err]
0032
AEr [Station Address Setting Error]
0033
CyC [MECHATROLINK CommCycleSettingErr]
0034
HCA [High Current Alarm]
0035
LT-1 [Cooling Fan Maintenance Time]
0036
LT-2 [Capacitor Maintenance Time]
0039
EF1 [External Fault (Terminal S1)]
003A
EF2 [External Fault (Terminal S2)]
003B
SToF [Safe Torque OFF Hardware]
003D
oL5 [Mechanical Weakening Detection 1]
003E
UL5 [Mechanical Weakening Detection 2]
0042
TrPC [IGBT Maintenance Time (90%)]
0043
LT-3 [SoftChargeBypassRelay MainteTime]
0044
LT-4 [IGBT Maintenance Time (50%)]
0045
boL [Braking Transistor Overload]
0049
dWAL [DriveWorksEZ Alarm]
004A
dWA2 [DriveWorksEZ Alarm 2]
004B
dWA3 [DriveWorksEZ Alarm 3]
0081
EP24v [External Power 24V Supply]
0085
bAT [Keypad Battery Low Voltage]
0087
CP1 [Comparator 1 Limit Error]
0088
CP2 [Comparator 2 Limit Error]
0089
TiM [Keypad Time Not Set]
008A
bCE [Bluetooth Communication Error]
◆
Error Codes
■
MEMOBUS/Modbus Communications Error Code List
lists the MEMOBUS/Modbus communications error codes.
When an error occurs, remove the cause of the error and restart communications.
Table 6.16 MEMOBUS/Modbus Communications Error Codes
Error Code
(Hex.)
Name
Cause
01
Function Code Error
The PLC set a function code that was not 03, 08, or 10 (Hex.)
02
Register Number Error
•
The register number that is trying to access is not registered.
•
A starting number that was not 0001 or 0002 (Hex.) was set when broadcasting.
03
Bit Count Error
•
Read and write data quantities are more than the 1 to 16 range. (Command message data quantity is disabled.)
•
The data that was read from non-consecutive holding registers contained more than 120 bytes.
•
The data to be written to non-consecutive holding registers contained more than 60 bytes.
•
In the write mode, the number of bytes in the message is not the number of data × 2.
21
Data Setting Error
•
Writing control data or parameters made the settings go out of the permitted setting range.
•
A parameter setting error occurred when writing a parameter.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...