14.8 Serial Commands
14.8.4 Positioning with a Program Table
14-24
*
If you set PnB54 to 1 (Enable Expansion Mode), the command name and the command setting range will change.
Refer to the following section for details.
12.4 Speed/Position Expansion Function Setting
14.8.4
Positioning with a Program Table
Program Table Setup Commands
The following table shows the Program Table Setup Commands.
SKIP
Positioning Stop
Stops the current positioning.
The remaining distance will be canceled.
OK
POUTnnnnnnnn
POUT Specification
Specifies the operation of programmable output signals /POUT0 to
/POUT7.
Settings:
N: Inactive
A: Active
Z: ZONE table
“:”: Continue
OK
Continued from previous page.
Serial Command
Function/Description
Positive
Response
x
0
POSIy
ST
SKIP
SKIP
SPDx
JOGPx
t
Speed
Remaining
distance
canceled
POUT n n n n n n n n
/
POUT0
/
POUT1
/
POUT2
/
POUT3
/
POUT4
/
POUT5
/
POUT6
/
POUT7
Serial Command
Function/Description
Positive Response
PGMSTORE
Program Table Save
Saves the program table in flash memory.
Once PGMSTORE is executed, the program
table will be retained after the control power
supply is turned OFF. Because the program
table is stored in flash memory, this command
must not be executed frequently.
Note: Do not turn OFF the control power supply while
PGMSTORE is being executed.
Execution can take a few seconds to slightly
longer than 10 seconds. The green LED will
flash during execution.
OK