7.1 Flow of Trial Operation
7.1.2 Flow of Trial Operation for Linear Servomotors
7-3
7
Trial Operation
7.1.2
Flow of Trial Operation for Linear Servomotors
The procedure for trial operation is given below.
•
Preparations for Trial Operation
3
Trial Operation with the Servomotor Con-
nected to the Machine
7.5 Trial Operation with the Servomotor Connected to the
Machine
Continued from previous page.
Step
Meaning
Reference
To power
supply
To host controller
Secure the motor flange to the
machine, and connect the
motor shaft to the load shaft
with a coupling or other means.
Step
Meaning
Reference
1
Installation
Install the Servomotor and SERVOPACK
according to the installation conditions. First,
operation is checked with no load. Do not
connect the Servomotor to the machine.
2
Wiring and Connections
Wire and connect the SERVOPACK. First,
Servomotor operation is checked without a
load. Do not connect the CN1 connector on
the SERVOPACK.
Chapter 4 Wiring and Connecting
3
Confirmations before Trial Operation
7.2 Inspections and Confirmations before Trial Operation
4
Power ON
−
5
Setting Parameters in the SERVOPACK
Continued on next page.
Step
No. of Parameter
to Set
Description
Remarks
Reference
5-1
Pn282
Linear Encoder Pitch
Set this parameter only if you are
using a Serial Converter Unit.
5-2
–
Writing Parameters to
the Linear Servomotor
Set this parameter only if you are
not using a Serial Converter Unit.
5-3
Pn080 = n.
X
Motor Phase Sequence
Selection
–
5-4
Pn080 = n.
X
Polarity Sensor Selec-
tion
–
5-5
–
Polarity Detection
This step is necessary only for a
Linear Servomotor with a Polarity
Sensor.
5-6
PnB0F and PnB10
Overtravel Signal Allo-
cations
–
5-7
Pn483, Pn484
Force Control
–