5.6 Specifications and Dimensional Drawings of Peripheral Devices
351
S
For 100VAC Class
Servopack Type
DR2-
Applicable
Servomotor
Power supply
capacity per
Servopack
*1
MCCB or
fuse
capacity
*2
Noise filter
type
(reference
Recommended noise
filter
*3
Power
ON/OFF
switch
Servopack
*1
kVA
capacity
*2
A
(reference
diagram)
Type
Spec.
switch
30 W
(0 04HP)
A3BC
SGM
−
A3B
j
0.25
5
Applicable
LF- 205A Single-phase
200 VAC
Contactor
35A
(0.04HP)
SGM
−
A3W
j
pp
g p
200 VAC
Class, 5 A
35A or
above
50 W
(0 07HP)
A5BC
SGM
−
A5B
j
0.3
Class, 5 A
above
(0.07HP)
SGM
−
A5W
j
100 W
(0.13HP)
01BC
SGM
−
01B
j
SGM
−
01W
j
0.5
Not
applicable
01BCP
SGMP
−
01B
j
SGMP
−
01W
j
applicable
200 W
(0.27HP)
02BC
SGM
−
02B
j
SGM
−
02W
j
0.75
8
LF- 210
Single-phase
200 VAC
Class 10 A
02BCP
SGMP
−
02B
j
SGMP
−
02W
j
Class, 10 A
300 W
(0.40HP)
03BC
SGM
−
03B
j
SGM
−
03W
j
1.4
15
LF- 220
Single-phase
200 VAC
Class 20 A
03BCP
SGMP
−
03B
j
SGMP
−
03W
j
Class, 20 A
Note
For power ON/OFF switch, use contactor 30A or above.
*1 Value at rated load.
*2 Braking characteristics (at 25
_
C): 200% for 2s min., 700% for 0.01s min.
*3 Yaskawa recommends noise filters manufactured by Tokin Corp.
Yaskawa Controls Co., Ltd. can supply these noise filters.
The types of cable are shown in the table below. Use it in combination with the table
above.
Cable Type
Conductor Allowable Temperature
C
Symbol
Name
p
_
C
PVC
Normal vinyl cable
---
IV
600 V vinyl cable
60
HIV
Temperature-resistant vinyl cable
75
Note
1) Use cable with 600 V min. withstand voltage for main circuits.
2) Consider allowable current reduction ratio if cables are bundled in PVC or metal ducts.
3) Use temperature-resistant cable under high ambient or panel temperature where nor-
mal vinyl cables rapidly deteriorate.
5