YASKAWA DI-A3 Скачать руководство пользователя страница 1

MANUAL NO.  TOBP C730600 39A

形式 

DI-A3

取扱説明書

ディジタル入力

安川インバータ オプションカード

製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.

Installation Manual

Digital Input

YASKAWA AC Drive-Option Card

Type  

DI-A3

Содержание DI-A3

Страница 1: ...A3 To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives this manual Installation Manual Digital Input YASKAWA A...

Страница 2: ...This Page Intentionally Blank...

Страница 3: ...tted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of Yaskawa No patent liability is assumed with respect to the use of the...

Страница 4: ...ffers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual NO OTHER WARRANTY EXPRESS OR IMPLIED IS OFFERED Yaskawa a...

Страница 5: ...is manual and local codes The following conventions are used to indicate safety messages in this manual Failure to heed these messages could result in serious or possibly even fatal injury or damage t...

Страница 6: ...r the content and presentation of the manual may be changed without notice to improve the product and or the manual When ordering a new copy of the manual due to damage or loss contact your Yaskawa re...

Страница 7: ...pper immediately Verify receipt of the correct model by checking the model number printed on the Name plate of the Option Card see Figure 1 If you have received the wrong model or the Option Card does...

Страница 8: ...n Card Figure 1 Figure 1 Option Card Terminal Block Figure 2 Figure 2 Terminal Block A Terminal block TB1 E Model number B Ground terminal installation hole F Installation hole C Terminal block TB2 G...

Страница 9: ...ight on the drive will go out after voltage in the DC bus drops below 50 V at which point it is safe to remove the front cover Due to the risk of electric shock be sure that all LEDs have gone out and...

Страница 10: ...y result in ESD damage to circuitry Never shut the power off while the drive is outputting voltage Failure to comply may cause the application to operate incorrectly or damage the drive Do not operate...

Страница 11: ...g CN5 connector on the drive then fasten it into place using one of the screws included with the option card Connect one of the lead lines using one of the screws to the ground terminal Note There are...

Страница 12: ...n the drives CIMR A 2A0056 to 0211 4A0031 to 0165 the cable can be routed inside the drive Figure 4 Figure 4 Wiring space 4 Place the front cover back onto the drive Note 1 Take care when wiring the o...

Страница 13: ...5 Wiring the Option Card and Drive Take the following steps to prevent erroneous operation caused by noise interference Use shielded wire for the signal lines Keep wiring under 50 m Make sure that con...

Страница 14: ...supply short circuit terminals SN and SC To use an external power supply connect the negative lead from the power supply to terminal SC on the option card Do not connect the positive lead to terminal...

Страница 15: ...d for the frequency reference setting 1 digit 0 to 9 1 1 digit 0 to 9 1 1 digits 0 to 9 1 1 digit 0 to 9 2 bit 0 bit 0 bit 0 D1 2 2 2 4 bit 1 bit 1 bit 1 D2 4 4 4 8 bit 2 bit 2 bit 2 D3 8 8 8 2 digits...

Страница 16: ...nput using the timing illustrated in Figure 6 The controller should switch off the SET signal and wait at least 1 ms before the changing digital inputs After changing the inputs it should wait at leas...

Страница 17: ...inal ends Note Wire ends should be properly trimmed so no wire extends out from the crimp terminals Table 4 Crimp Terminal Sizes Terminal Signal Screw Size Tightening Torque Nxm Bare Cable Wiring Gaug...

Страница 18: ...contact with other wiring Insufficient insulation may cause a short circuit that can damage the option card and the drive NOTICE Follow the tightening torque specifications in this manual for all term...

Страница 19: ...s connected to Table 5 Related Parameters No 1 Binary input is not possible if o1 03 is set to 2 or 3 The setting of F3 01 will be disregarded and setting units will be determined by o1 03 1 Parameter...

Страница 20: ...reconnect the option card Digital Operator Display Fault Name oFb01 Option Card Connection Error at CN5 B Cause Possible Solution Option card at port CN5 B was changed during run Switch the power off...

Страница 21: ...ame time Refer to table below More details can be found in the option card section of the drive instruction manual Option Card 2 The AI A3 and DI A3 option can also be installed to option ports CN5 B...

Страница 22: ...T and SIGN signals Input Signal Type Parameter Settings Binary 16 bit 4 digit BCD Binary 12 bit 3 digit BCD Binary 8 bit 2 digit BCD Input Signal Sink source external power supply Photocoupler input 2...

Страница 23: ...ation Manual 23 Revision History The revision dates and numbers of the revised manuals are given on the bottom of the back cover Date of Publication Rev No Section Revised Content July 2008 First edit...

Страница 24: ...Brazil Phone 55 11 3585 1100 Fax 55 11 5581 8795 YASKAWA ELECTRIC EUROPE GmbH Hauptstra e 185 65760 Eschborn Germany Phone 49 6196 569 300 Fax 49 6196 569 398 YASKAWA ELECTRIC UK LTD 1 Hunt Hill Orch...

Отзывы: