666
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
■
Digital Output Card Selection
Refer to
“
H2: Multi-function Digital Output
”
for more information about the functions that output from the
terminals when
F5-09 = 2 [DO-A3 Output Mode Selection = Programmable (F5-01 to F5-08)]
. Use
F5-01 to F5-
08
to set the output items.
No.
Name
Setting Range
Default
F5-01
Terminal P1-PC Function Select
0 - 192
0: During Run
F5-02
Terminal P2-PC Function Select
0 - 192
1: Zero Speed
F5-03
Terminal P3-PC Function Select
0 - 192
2: Speed Agree 1
F5-04
Terminal P4-PC Function Select
0 - 192
4: Frequency Detection 1
F5-05
Terminal P5-PC Function Select
0 - 192
6: Drive Ready
F5-06
Terminal P6-PC Function Select
0 - 192
37: During Frequency Output
F5-07
Terminal M1-M2 Function Select
0 - 192
F: Not Used
F5-08
Terminal M3-M4 Function Select
0 - 192
F: Not Used
■
F5-01: Terminal P1-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-01
(0399)
Terminal P1-PC Function
Select
Sets the function of terminal P1-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
0
(0 - 1FF)
■
F5-02: Terminal P2-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-02
(039A)
Terminal P2-PC Function
Select
Sets the function of terminal P2-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
1
(0 - 1FF)
■
F5-03: Terminal P3-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-03
(039B)
Terminal P3-PC Function
Select
Sets the function of terminal P3-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
2
(0 - 1FF)
■
F5-04: Terminal P4-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-04
(039C)
Terminal P4-PC Function
Select
Sets the function of terminal P4-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
4
(0 - 1FF)
■
F5-05: Terminal P5-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-05
(039D)
Terminal P5-PC Function
Select
Sets the function of terminal P5-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
6
(0 - 1FF)
■
F5-06: Terminal P6-PC Function Select
No.
(Hex.)
Name
Description
Default
(Range)
F5-06
(039E)
Terminal P6-PC Function
Select
Sets the function of terminal P6-PC on the DO-A3 option. Set
F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)]
to enable this function.
37
(0 - 1FF)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...