When you install a DO-A3 to the drive, you can output isolated digital signals to monitor the drive operation
status.
•
6 points of photocoupler output (48 V, 50 mA or less)
•
2 points of relay contact output (250 Vac, 30 Vdc: 1 A or less)
Refer to the DO-A3 option manual for more information about how to install, wire, and set the DO-A3 card.
■
Output Mode Selection via Parameters
Signal output from the DO-A3 card can be set as follows with
F5-09 [DO-A3 Output Mode Selection]
.
Table 11.20 Details of F5-09 and the DO-A3 Terminal Output
DO-A3 Terminal Block
DO-A3 Terminal Name
F5-09 = 0 [Predefined
Individual Outputs] (Default
Setting)
F5-09 = 1 [Binary Output]
F5-09 = 2 [Programmable
(F5-01 to F5-08)]
TB1
M1-M2
Zero speed detection in progress
During Run
Depending on the setting of F5-07
[Terminal M1-M2 Function
Select]
M3-M4
During speed agreement
Minor fault (excluding bb
[Baseblock])
Depending on the setting of F5-08
[Terminal M3-M4 Function
Select]
TB2
P1-PC
oC [Overcurrent], GF [Ground
Fault]
Coded output
Note:
Refer to
for
details.
Depending on the setting of F5-01
[Terminal P1-PC Function Select]
P2-PC
ov [Overvoltage]
Depending on the setting of F5-02
[Terminal P2-PC Function Select]
P3-PC
oL2 [Drive Overloaded] or oH2
[External Overheat (H1-XX=B)]
Depending on the setting of F5-03
[Terminal P3-PC Function Select]
P4-PC
Not used
Depending on the setting of F5-04
[Terminal P4-PC Function Select]
P5-PC
oS [Overspeed]
Zero speed detection in progress
Depending on the setting of F5-05
[Terminal P5-PC Function Select]
P6-PC
oH, oH1 [Heatsink Overheat] or
oL1 [Motor Overload]
During speed agreement
Depending on the setting of F5-06
[Terminal P6-PC Function Select]
Table 11.21 Binary Output [F5-09 = 1]
Coded Output (Binary)
Description
DO-A3 Terminal Block TB2
Terminals P1-PC
Terminals P2-PC
Terminals P3-PC
Terminals P4-PC
0
No fault
0
0
0
0
1
oC [Overcurrent], GF
[Ground Fault]
1
0
0
0
2
ov [Overvoltage]
0
1
0
0
3
oL2 [Drive Overload]
1
1
0
0
4
oH, oH1 [Heatsink
Overheat]
0
0
1
0
5
oS [Overspeed]
1
0
1
0
6
Not used
0
1
1
0
7
rr [Dynamic Braking
Transistor Fault], rH
[Braking Resistor Overheat]
1
1
1
0
8
External Fault [EF1 to
EF10]
0
0
0
1
9
CPFxx, oFAxx, oFbxx,
oFCxx [Drive Hardware
1
0
0
1
A
oL1 [Motor Overload]
0
1
0
1
B
Not used
1
1
0
1
C
Uv1, Uv2 [Undervoltage],
Uv3 [Soft Charge
Answerback Fault]
0
0
1
1
D
dEv [Speed Deviation]
1
0
1
1
E
PGo [Encoder (PG)
Feedback Loss]
0
1
1
1
F
Not used
1
1
1
1
*1
The digits represented by xx vary depending on the type of fault that occurs.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...