5.3 MEMOBUS/Modbus Communications
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
307
Description
Calculation
Overflow
Description
Calculation
Overflow
XOR w initial value
1111 1111 1111 1101
Shift 1
0100 0000 1001 1110
1
Shift 1
0111 1111 1111 1110
1
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR result
1110 0000 1001 1111
-
XOR result
1101 1111 1111 1111
-
Shift 2
0111 0000 0100 1111
1
Shift 2
0110 1111 1111 1111
1
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR result
1101 0000 0100 1110
-
XOR result
1100 1111 1111 1110
-
Shift 3
0110 1000 0010 0111
0
Shift 3
0110 0111 1111 1111
0
Shift 4
0011 0100 0001 0011
1
Shift 4
0011 0011 1111 1111
1
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR result
1001 0100 0001 0010
-
XOR result
1001 0011 1111 1110
-
Shift 5
0100 1010 0000 1001
0
Shift 5
0100 1001 1111 1111
0
Shift 6
0010 0101 0000 0100
1
Shift 6
0010 0100 1111 1111
1
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
XOR result
1000 0101 0000 0101
-
XOR result
1000 0100 1111 1110
-
Shift 7
0100 0010 1000 0010
1
Shift 7
0100 0010 0111 1111
0
XOR w A001 (Hex.)
1010 0000 0000 0001
-
Shift 8
0010 0001 0011 1111
1
XOR result
1110 0010 1000 0011
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
Shift 8
0111 0001 0100 0001
1
XOR result
1000 0001 0011 1110
-
XOR w A001 (Hex.)
1010 0000 0000 0001
-
Perform operations with next data (function code)
XOR result
1101 0001 0100 0000
-
CRC-16
1101 0001 0100 0000
-
D 1 4 0
(Lower) (Upper)
-
Continue from here with next data.
Response Data
The drive does the CRC-16 calculation for the response message and makes sure that the data does not have
errors. Make sure that the calculated value is the same value as the CRC-16 in the response message.
◆
Examples of Messages for Commands/Responses
The items in this section are examples of messages for commands/responses.
■
Read Multiple Holding Registers
Uses function code 03 (Hex.) to read the contents of a maximum of 16 holding registers.
shows example messages when the drive reads status signal from the drive of slave 2, the error contents,
fault contents, and frequency references.
Table 5.6 Message Example When Reading the Contents of Holding Register
Byte
Command Message
Setting Data
(Hex.)
Response Message (Normal)
Setting Data
(Hex.)
Response Message (Fault)
Setting Data
(Hex.)
0
Slave address
02
Slave address
02
Slave address
02
1
Function code
03
Function code
03
Function code
83
2
Starting No.
Upper
00
Data Qty
08
Error code
03
3
Lower
20
First storage
register
Upper
00
CRC-16
Upper
F1
4
Data Qty
Upper
00
Lower
65
Lower
31
5
Lower
04
Next storage
register
Upper
00
-
6
CRC-16
Upper
45
Lower
00
-
7
Lower
F0
Next storage
register
Upper
00
-
8
-
Lower
00
-
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...