28
YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
2042
33.0
8
73
212
285
2056
47.0
8
108
347
455
2070
60.0
8
171
455
626
Table 7.10 Three-Phase 400 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
4001
1.2
8
9
11
20
4002
1.8
8
11
16
27
4004
3.4
8
15
31
46
4005
4.8
8
18
42
60
4007
5.6
8
18
49
67
4009
7.3
8
25
65
90
4012
9.2
8
32
85
117
4018
14.8
8
52
149
201
4023
18
8
92
207
299
4031
24
8
75
240
315
4038
31
8
108
319
427
■
Normal Duty Rating (ND)
Table 7.11 Single-Phase 200 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
B001
1.2
2
8
6
14
B002
1.9
2
14
11
25