Configuration Parameter
Description
b5-95 = 0 [EZ Wake-up Mode = Absolute]
When the PID feedback is less than the value of
b5-94 [EZ Wake-up Level]
for longer than the time set in
b5-96 [EZ Sleep Wake-up Time]
, the drive restarts operation from sleep.
b5-95 = 1 [EZ Wake-up Mode = Setpiont Delta]
When the PID feedback is less than the value set as the PID setpoint value minus
b5-94
for the time set in
b5-96
, the drive restarts operation from sleep.
Figure 12.32 EZ Sleep/Wake-up Operation: PID Output is Normal and b5-92 = 0.0 Hz
*1
The values of
b5-94
and
b5-95
set operation.
*2
In the example,
b5-92
is at the default setting of 0.0 Hz.
b5-91
is the EZ sleep level.
■
b5-01: PID Mode Setting
No.
(Hex.)
Name
Description
Default
(Range)
b5-01
(01A5)
PID Mode Setting
Sets the type of PID control.
0
(0 - 8)
0 : PID control disabled
1 : Standard
Enables PID control. The drive performs D control on the difference between the feedback value and the PID
setpoint output via
U5-02 [PID Input]
.
2 : Standard (D on feedback)
Enables PID control. The drive performs D control on the feedback output via
U5-06 [PID Fdbk-Diff PID Fdbk]
.
3 : Fref + PID Trim
Enables PID control. The drive adds the frequency reference to the PID output. The drive performs D control on
the difference between the feedback value and the PID setpoint output via
U5-02 [PID Input]
.
4 : Fref + PID Trim (D on feedback)
Enables PID control. The drive adds the frequency reference to the PID output. The drive performs D control on
the feedback output via
U5-06 [PID Fdbk-Diff PID Fdbk]
.
5 : Same as 7series & prior, b5-01=1
6 : Same as 7series & prior, b5-01=2
7 : Same as 7series & prior, b5-01=3
8 : Same as 7series & prior, b5-01=4
Note:
Use settings 5 to 8 when the drive is a replacement for a previous generation drive.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...